Viking 210GM, 250GM
18
8. POWER SOURCE CONTROLS, INDICATORS AND FEATURES
Wirespeed Control
Spot Timer Control
Dwell Timer Control
Mode Selector
Switch
Brass Torch Adaptor
Indicator Light
On/Off & Coarse
Voltage Control Switch
Fine Voltage
Control Switch
Negative Welding
Current Terminal
Positive Welding
Current Terminal
Optional Meter
Torch Polarity Lead
Indicator Light
On/Off & Coarse
Voltage Control Switch
Fine Voltage
Control Switch
Negative Welding
Current Terminal
Wirefeeder Control
Socket
Positive Welding
Current Terminal
Optional Meter
Ammeter/Voltmeter
Switch
Figure 3 - Compact Viking controls
Figure 4 - Remote Viking controls
8.1 Indicator
Light
The indicator light is provided to indicate when the Viking is connected to the Mains supply
voltage.
WARNING 4
When the light is lit, the machine is connected to the Mains supply voltage and the internal electrical
components are at Mains voltage potential.
8.2 Standby/Coarse Voltage Control Switch and Fine Voltage Control Switch
The Coarse Voltage Control switch turns off the fan and auxiliary power in the
STANDBY
position. It sets the voltage level to the welding terminals in the remaining positions, increasing
the voltage as it is rotated in the clockwise direction. The Fine Voltage Control switch increases
the voltage (in smaller increments than the Coarse switch) as it is rotated in the clockwise
direction.
CAUTION 2
The Coarse & Fine Voltage Control switches MUST NOT BE SWITCHED during the welding process.
8.3 Digital Ammeter and Voltmeter (Optional)
Where fitted an average reading ammeter and voltmeter is provided to allow accurate monitoring
(5% tolerance) of welding current and voltmeter to facilitates precise welding condition
adjustment. Refer to section 11.1 on page 27 for the Improved Current Accuracy Calibration
Procedure for the Digital Meter.
Value displayed for 157 Amp
Value displayed for 23.4 Volts
Figure 5 - Examples of the digital read outs
The Digital Meter will display both welding current and voltage. To toggle between the current
and voltage readings depress the push button switch mounted below the meters display. See
Figure 5 for an example of current and voltage display.
Summary of Contents for Viking 210GM
Page 21: ...Viking 210GM 250GM 16 6 WELDING GUIDE VIKING 210GM...
Page 22: ...Viking 210GM 250GM 17 7 WELDING GUIDE VIKING 250GM...
Page 40: ...Viking 210GM 250GM 35 14 VIKING 210GM CIRCUIT DIAGRAM...
Page 41: ...Viking 210GM 250GM 36 15 VIKING 250GM CIRCUIT DIAGRAM...
Page 42: ...Viking 210GM 250GM 37 16 PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM CAT NO 10 6100...