22
6. ON/OFF Switch
This switch connects the Primary supply voltage to the inverter when in the ON position. This enables
the Power Supply.
WARNING 5
When the welder is connected to the Primary supply voltage, the internal electrical components
may be at 500V potential with respect to earth.
7.
Input Cable
The input cable connects the Primary supply voltage to the equipment.
8.
14/19 Pin Remote Control Select Switch
User selectable switch.
Position this switch for the remote control device socket to be utilized. The unselected Remote Control
Socket is disabled at this time and cannot be utilized. Do not alter the position of this switch while one
of the Remote Control Sockets is being utilized.
9.
24VAC Remote Device C/B
Push to reset. Controls the 24VAC power source for the wire feeders controlled through the Remote
Control Sockets.
10.
115VAC Remote Device C/B
Push to reset. Controls the 115VAC power source for the wire feeders controlled through the Remote
Control Sockets.