30
5.03 MIG Welding
5.04 Save-Load Operation
A total number of 5 programs can be saved into the 400 MST memory.
SAVE
the Current Weld Parameters into Memory
•
Press and HOLD the
SAVE
button. Beep will sound and Digital Meter display will show a number 1.
•
Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter.
•
After selecting the desired memory location (i.e. 1 to 5), press the right scroll button and the
machine will give a beep to confirm the weld parameters from the control panel are saved.
LOAD
(retrieve) a Program to Control Panel
•
Press and HOLD the
LOAD
button. Beep will sound and Digital Meter display will show a number 1.
•
Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter.
•
After selecting the desired memory location (i.e. 1 to 5), press the right scroll button and the
machine will give a beep to confirm the weld parameters are loaded onto the control panel.
•
Connect work lead to negative terminal
•
Connect electrode lead to positive terminal
•
Switch machine on
•
Set weld voltage
•
Set Inductance
•
Connect Wire feeder
•
Set wire feed speed (IPM)
Use the Scroll Buttons to move to the parameter to be set. The LED will show which function is being
adjusted on the weld sequence graph. Use the control knob to adjust each parameter.
Commence welding