INSTALLATION
The output terminals are located on the front panel of the welding power source.
CABLE TO WIREFEEDER CABLE TO WORK
PROCESS
POLARITY
CABLE CONNECTIONS
CABLE TO A2281
CABLE TO WORK
1. GMAW* – Steel, Stainless Steel,
Aluminum & gas shielded Flux
Cored electrode wires
1. D.C. Electrode Positive
(DCEP) – Reverse Polarity
1. Connected to (+)
Pos. output
terminal
1. Connected to (-)
Neg. output
terminal
2. FCAW* – Gasless Flux Cored
electrode wire
2. D.C. Electrode Negative
(DCEN) – Straight Polarity
2. Connected to (-)
Neg. output
terminal
2. Connected to (+)
Pos. output
terminal
Table 3-3: Process Cable Connections
Art # A-07479
Cable from wirefeeder
connected to
+
terminal
Cable to work
Connected for D.C.
Electrode Positive
(DCEP) Welding
Figure 3-15: Polarity Connections for DCEP