Up Slope
This parameter operates in (4T)
TIG modes only and is used to
set the time for the weld current
to ramp up, after the torch trigger
switch has been pressed then
released, from Initial Current to
High or BASE current.
V
SEC
%
Hz
Volts
0.0 to 15.0 seconds
Base Current
This parameter sets the TIG
WELD current when PULSE is
OFF. This parameter also sets the
STICK weld current.
Amps
5 to 200A (DC TIG mode)
30 to 200A (AC LIFT TIG mode)
10 to 200A (AC HF TIG mode)
High Current
This parameter sets the High weld
current when in PULSE mode.
Amps
10 to 200A (DC TIG mode)
30 to 200A (AC TIG mode)
Low Current
The lowest point in the pulse is
called the Low Current.
Amps
5 to 200A (DC HF TIG mode)
30 to 200A (AC LIFT TIG mode)
10 to 200A (AC HF TIG mode)
Pulse Width
This parameter sets the
percentage on time of the PULSE
FREQUENCY for High weld
current when the PULSE is ON.
V
SEC
%
Hz
Volts
15 to 80%
Pulse Frequency
This parameter sets the PULSE
FREQUENCY when the PULSE is
ON..
V
SEC
%
Hz
Volts
0.5 to 200 Hz
Down Slope
This parameter operates in TIG
modes only and is used to set
the time for the weld current
to ramp down, after the torch
trigger switch has been pressed,
to crater current. This control is
used to eliminate the crater that
can form at the completion of a
weld.
V
SEC
%
Hz
Volts
0.0 to 25.0 seconds