Notice NOT 034
THERMAL ARC 180 AC/DC
Rev : 00
Date : 03/12/02
USING
USER’S MANUAL
Page
22/36
When welding, the component’s temperature rise starts the ventilation and fixes the fan’s speed which
will change according to temperature.
This method is a good solution between cooling and protection from dust’s circulation in the machine.
NOTE
: When ambient temperature is high, the fan can operate for a short period even if you are not
welding.
In MMA (stick) mode, ventilation is permanent
13.
WELDING WITH PULSE DC CURRENT
The THERMAL ARC 180 AC/DC units have got an integrated pulse current function.
To set the pulse current, press the setting key
F15
. The indicator
F27
illuminates (indicator
F26
OFF).
To remove the pulse current, press the setting key
F15
until indicator
F27
fade out.
X
Adjustment of the pulse high current
Adjust the high current with the potentiometer
F9
.
The value can be read on display
F5
.
Y
Adjustment of the pulse low current
When
F26
OFF and
F27
ON, press the setting key
F15
for 3 s. Maintain the key pressed and adjust
the low current‘s value with the potentiometer
F9
.
The value can be read on the display
F5
.
When the potentiometer is at the minimum, the current is 3A, and at the maximum, it is high pulse
current value.
The low current is pre-adjusted at 30A.
Summary of Contents for 180 AC
Page 1: ...THERMAL ARC 180 AC DC USER S MANUAL ...
Page 34: ...21 WIRING DIAGRAM ...