Notice NOT 034
THERMAL ARC 180 AC/DC
Rev : 00
Date : 03/12/02
DESCRIPTION
USER’S MANUAL
Page
13/
36
5.
TECHNICAL CHARACTERISTICS
DIMENSIONS ( in mm )
PRIMARY
Single phased power supply
V
230 V
(+/- 13%)
Frequency
Hz
50/60
MMA (stick) welding
TIG welding
Maximum primary current
A
29.5
18.6
Maximum power consumption
kVA
6.8
4.2
Main supply protection
A
25
16
Power factor (cos Ø)
0,98
SECONDARY
Off load voltage
V
50 / 60
Minimum secondary current
A
3
MMA (stick) and TIG welding
Welding current at 50 %
A
180
Welding current at 60 %
A
160
Welding current at 100 %
A
140
Courant alternatif / AC current
Frequency
Hz
From 20 to 250
Waves form
square waves
Balance cleaning/penetration
Cleaning from 20% (penetration.80%) to 60% (penetration.40%)
Pulse current
low current
A
From 3 to welding current
Frequency
Hz
From 0.2 to 99.9
Cycle ratio
%
From 20 to 80
Protection degree
IP 23
Insulation class
H
Standards
EN 60974-1/EN 50199
Weight
kg
19
Dimensions L x W x H
mm
407 x 209 x 372
Summary of Contents for 180 AC
Page 1: ...THERMAL ARC 180 AC DC USER S MANUAL ...
Page 34: ...21 WIRING DIAGRAM ...