THERMAL INNOVATIONS (UK) LTD | THERMAFLOW® ELECTRIC COMBINATION BOILER |
Tel: 0870 850 5207
11
PART 2 - INSTALLATION
2.1.1 Sheet metal parts
Warning:
when installing or servicing this boiler care should be taken when handling the edges of
metal parts to avoid any possibility of personal injury.
2.1.2 Statutory requirements
The installation of this boiler must be carried out by a competent person in accordance with the
current rules in force in the countries of destination at the time of installation, and in accordance with
the relevant requirements of the current issue of:
The Building Regulations
The Local Water Company bye-laws
The Building Standards Regulations (Scotland)
The Health and Safety at Work Act
Manufacturers instructions, supplied
Manufacturer’s instructions must not be taken as overriding statutory requirements.
2.1.3 DATA
The data label is on the front case of the boiler.
2.1.4 ELECTRICAL SUPPLY
•
Power supply and wiring
The power supply to the premises must meet the minimum requirements of the unit being installed, with
special attention given to the supply current, cable size and MCB recommendation. The supply voltage to the
appliance must never drop below
207 Volts.
Important
The electrical supply requirements:-
The 9 KW and 12 KW boilers meet the requirements of EN 61000-3.3
The 9 KW and 12 KW boilers must be installed in premises having a service supply of
≥
100A
per phase.
The 12 KW boiler must be installed in premises having a system impedance of not more than
0.1939 + J
0.1939
Ω
WARNING: This boiler must be earthed
WARNING: Means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules
WARNING: Electrical work must be carried out by a person competent to do so
All system components shall be of an approved type.
The electrical installation shall be in accordance with the current rules in force in the countries of
destination at the time of installation.
2.1.5 Electrical supply
Means of disconnection of the electrical supply to the boiler must be incorporated in the
fixed wiring in accordance with the wiring rules.