3.02 Setup for Operation
Gas Tungsten Arc Welding (GTAW) Lift Start
WARNING
Read and follow all safety precautions on pages 2-5 of this manual before
preceding with operation.
1.
Install and connect unit according to the installation instructions in
section 2.04, page 17, of this manual.
2.
Select proper tungsten electrode (refer to Electrode Selection Table
2, Page 31).
3.
Prepare tungsten electrode and insert into torch. For the majority of
electrodes in use, the electrode is connected to the NEGATIVE
output terminal.
4.
Wear dry insulating gloves and clothing.
5.
Connect TIG torch.
6.
Connect remote control device to 14-Pin receptacle.
NOTE
The maximum output that can be obtained using the remote control is set
by the main current knob.
1
4
8
7
7.
Connect work clamp to clean, bare metal on workpiece. For the
majority of electrodes in use, the work clamp is connected to the
POSITIVE output terminal.
8.
Refer to the Operator Control section, page 22, and set the controls
per the following:
a. PROCESS SELECTOR switch [4] to Lift Start Gas Tungsten Arc
Welding position.