17
MANUAL 0-2510
2.03 Transporting Methods
These units are equipped with a handle for carrying purposes.
WARNING
ELECTRIC SHOCK can kill.
•
DO NOT TOUCH live electrical parts.
•
Disconnect input power conductors from de-energized supply line
before moving welding power source.
WARNING
FALLING EQUIPMENT can cause serious personal injury and equipment
damage.
•
Lift unit with handle on top of case.
•
Use hand cart or similar device of adequate capacity.
•
If using a fork lift vehicle, place and secure unit on a proper skid
before transporting.
2.04 Electrical Input Connections
WARNING
ELECTRIC SHOCK can kill; SIGNIFICANT DC VOLTAGE is present after
removal of input power.
•
DO NOT TOUCH live electrical parts.
•
SHUT DOWN welding power source, disconnect input power
employing lockout/tag out procedures. Lockout/tag out procedures
consist of padlocking line disconnect switch in open position,
removing fuses from fuse box, or shutting off and red-tagging circuit
breaker or other disconnecting device.
Electrical Input
Requirements
Operate the welding power source from a single or three-phase 50/60 Hz,
AC power supply. The input voltage must match one of the electrical input
voltages shown on the input data label on the unit nameplate. Contact the
local electric utility for information about the type of electrical service
available, how proper connections should be made, and inspection
required.
The line disconnect switch provides a safe and convenient means to
completely remove all electrical power from the welding power supply
whenever necessary to inspect or service the unit.
NOTE
These units are equipped with a four-conductor with earth power cable
that is connected at the welding power source end for single or three-phase
electrical input power.
INTRODUCTION
Summary of Contents for Thermal Arc 400GMS CC