14
Side Hinge Door Alignment Procedure
1.
Open the door to approximately 135°.
2.
Using a Torx T20 screwdriver, loosen the three screws
(A) on the lower hinge by 1 to 2 full turns.
Note:
All adjustments are made with the lower hinge
only. The upper hinge is fixed in place and cannot be
adjusted.
3.
Using a #2 Phillips screwdriver, turn the cam screw
(B) right or left to adjust the hinge position in the
desired direction.
Note:
1mm of hinge movement (left or right) will move
the door up or down approximately 1.5mm at the door
catch.
4.
Re-tighten the screws before closing the door to test.
Be careful not to overtighten.
5.
Check for proper door alignment. Repeat adjustment
procedure as necessary.
%
$
%