Installation Instructions
English | 14 |
Wall installation
1. Turn power OFF at the service panel. Lock service panel
to prevent power from being turned ON.
2. Ensure that the minimum height of 30” (762 mm) from
the bottom of the hood to the cooking surface will be
maintained.
3. Mark a reference centerline on the wall.
4. Tape template in place, aligning the template centerline
and bottom of template with hood bottom line and with
the centerline marked on the wall.
Ve
r
tical Cent
er
line
CL
L
L
A
W
R
A
E
R
E
T
A
L
P
M
E
T
G
N
I
T
N
U
O
M
E
G
D
E
M
O
T
T
O
B
N
G
I
L
A
E
N
I
L
L
I
C
N
E
P
H
T
I
W
M
O
T
T
O
B
G
N
I
T
A
C
I
D
N
I
D
O
O
H
E
H
T
F
O
t
h
g
i
e
H
n
o
it
a
ll
a
t
s
n
I
T
R
O
P
P
U
S
L
L
A
W
R
A
E
R
R
O
S
D
U
T
S
H
G
U
O
R
H
T
S
E
L
O
H
T
O
L
I
P
"
6
1
/
3
)
O
W
T
(
2
L
L
I
R
D
e
n
i
L
l
a
t
n
o
z
ir
o
H
A
B
C
A. Centerline
B. Fastener locations
C. Mounting height reference (hood bottom line)
5. Mark centers of the fastener locations through the
template to the wall.
IMPORTANT: All screws must be installed into wood.
If there is no wood to screw into, additional wall framing
supports may be required.
6. Remove the template.
7. Drill
3
⁄
16
” (4.8 mm) pilot holes at all locations where
screws are being installed into wood.
8. Install the 2 - 5 x 45 mm mounting screws. Leave a
1
⁄
4
”
(6.4 mm) gap between the wall and the back of the
screw head to slide range hood into place.
1
/
4
"
(6.4)
Vent cover bracket installation
1. Attach vent cover bracket to wall flush to the ceiling
using 2 - 5 x 45 mm screws.
A
C
D
B
A. 8 x 40 mm drywall anchors
B. Centerline on wall
C. Vent cover support bracket
D. 5 x 45 mm screws
Complete Installation
1. Determine and make all necessary cuts in the wall for
the vent system. Install the vent system before installing
the hood. See “Venting Requirements” section.
2. Determine the required height for the home power
supply cable and drill a 1
1
⁄
4
” (3.2 cm) hole at this location.
3. Run the home power supply cable according to the
National Electrical Code or CSA Standards and local
codes and ordinances. There must be enough
1
⁄
2
”
conduit and wires from the fused disconnect (or
circuit breaker) box to make the connection in the
hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is
complete.
4. Use caulk to seal all openings.
Installing the range hood
1. Using 2 or more people, hang range hood on 2
mounting screws through the mounting slots on back of
the hood.
A Upper mounting screws
B Security screws
A
B