THE BROIL ELEMENT
Refer to page 2-2 to access the broil element.
1.
With no power applied, remove the wires from
the terminals of the broil element.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter leads to the broil element
terminals. The meter should indicate 15
Ω
.
4.
If the reading is not correct, remove and replace
the broil element.
THE HIDDEN BAKE ELEMENT
(“C” MODELS ONLY)
Refer to page 2-4 to access the bake element.
1.
With no power applied, remove the wires from
the terminals of the hidden bake element.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter leads to the bake element
terminals. The meter should indicate 24
Ω
.
4.
If the reading is not correct, remove and replace
the bake element.
Page 51