2
PRODUCT SPECIFICATIONS
Model
WDFT060-VF WDFT100-VF WDFT320-VF
BTU
(
available
)
6000 10000
32000
Gas type
Using natural gas
Using natural gas
Using natural gas
Press regulator setting
4 in w.c.
4 in w.c.
4 in w.c.
Inlet gas pressure(inches of water) for purpose of input adjustment
Maximum
7 in w.c.
7 in w.c.
7 in w.c.
Minimum
5 in w.c.
5 in w.c.
5 in w.c.
Gas type
Using propane gas
Using propane gas
Using propane gas
Press regulator setting
11 in w.c.
11 in w.c.
11 in w.c.
inlet gas pressure(inches of water) for purpose of input adjustment
Maximum
14 in w.c.
14 in w.c.
14 in w.c.
Minimum
11 in w.c.
11 in w.c.
11 in w.c.
Ignition
Electric Piezo
Electric Piezo
Electric Piezo
Dimension inches
(H×W×D)
15.7×7.5×25.6 18.1×7.5×28.7 30.7×9.1×29.5
Important Note:
1) An unvented room heater having an input rating of more than 10,000 Btu/hr
(2,931 W) shall not be installed in a bedroom or bathroom; or
2) An unvented room heater having an input rating of more than 6000 Btu/hr
(1,758 W) shall not be installed in a bathroom.