INITIAL START-UP
All THERMA-TEK appliances are adjusted and tested before leaving the factory. Adjustments and
calibrations may be necessary upon installation to meet local conditions, low gas characteristics; problems
caused by rough handling or vibration during shipping, and are to be performed only by qualified service
personnel. These adjustments are the responsibility of the customer and or dealer and are not covered by our
warranty.
Check all gas connections for leaks with a soapy water solution before lighting pilots.
Do NOT use an open
flame to check for leaks.
Putting an open flame beside a new gas connection is extremely dangerous. Before
lighting any pilots, make sure that burner valves and thermostats are in the off position.
LIGHTING THE PILOTS
CAUTION: When lighting the pilots and checking for leaks, do not stand with your face close to the
Combustion chamber.
OPEN TOP:
Remove top grates
Make sure pilot adjust valve located on the manifold is open.
Light the pilot and adjust flame to approximately ½”.
GRIDDLE:
Looking through slot in the valve panel, locate pilot lighting holes in the burner front shield.
Make sure pilot adjust valve located on the manifold is open.
Light the pilot and adjust flame to approximately 3/4” high.
BROILER:
Remove grates.
Make sure pilot adjust valve located on the manifold is open.
Light the pilot and adjust the flame to approximately ¾” high.
SHUTDOWN
Nightly shutdown: Turn burner valves and thermostat to off position, pilots will remain lit.
Complete shutdown: Turn burner valves and thermostats to off position. Turn main gas supply to
range off.
5
Summary of Contents for TC36-6
Page 10: ...9 HOT PLATE Counter Series ...
Page 12: ...GRIDDLE Counter Series 11 ...