Therma-Stor Ultra-Aire DEH 3000 Installer'S & Owner'S Manual Download Page 3

3. Installation

3.1 Location

The Ultra-Aire should be located near the existing air handling system 
to minimize the required ductwork for connecting the Ultra-Aire to 
the existing air handling system.The controls for the Ultra-Aire are 
remote from the unit and must be located in the space that is to be 
conditioned. The controls are low voltage (24 volt) and should be 
connected to the Ultra-Aire with low voltage thermostat cable.

If fresh air ventilation is desired, thought should be given to the 
location for the fresh air ducting. A 6" round duct will have to be 
installed on the Ultra-Aire and run to the outside of the structure to 
bring in fresh air. Use an 8" insulated round duct for lengths of more 
than 25' or if more than 100 CFM is needed.

3.2 Electrical Requirements

The Ultra-Aire plugs into a common grounded outlet on a 15 Amp 
circuit. It draws between 6 and 7 Amps under normal operating 
conditions. If used in a wet area (pool, spa room, or basement prone 
to flooding), a ground fault interrupter protected circuit is required.

The installer must supply the wiring between the Ultra-Aire and the 
control panel. Be sure to safely route the control wires to prevent 
damage during installation. Be careful not to cross the wires when 
connecting the Ultra-Aire and the remote control panel or damage to 
the transformer may result.

The remote controls of the Ultra-Aire are powered by a low voltage 
circuit (24 Vac) and must NEVER contact or be connected to a high 
voltage circuit. The control wires leaving the Ultra-Aire and the 
remote control panels are color coded to prevent confusion. Some of 
the control wires leaving the Ultra-Aire may not be used with certain 
control panels and should be left safely disconnected with wire 
nuts taped onto the stripped ends. Be sure to consult the electrical 
schematic in this manual or on the front panel of the Ultra-Aire before 
making the control connections.

 

 WARNING! 

Do not allow the yellow lead 

from the Ultra-Aire to contact the red lead or orange 

lead from the Ultra-Aire or damage to the transformer 

will result.
NOTE: Reset the ventilation timer before attempting to 

program after initial installation. The timer may not  ..

operate correctly until it is reset.

3.3 Condensate Removal

Condensate drains by gravity via the clear hose extending from the 
unit. Route the hose to a floor drain. Use care to keep the hose as flat 
to the floor as possible; excessive humps will prevent proper drainage. 
We do not call for a trap since there is an internal trap with this unit. 
If the Ultra-Aire is located too far from a floor drain for the attached 
hose to reach, inexpensive 1⁄2" PVC pipe can be used to extend it. It is 

commonly available in 10' lengths from building supply, plumbing and 
hardware stores. It will slide tightly inside the end of the drain hose. 
If more than one length of pipe is required, they can be joined with a 
short piece cut from the end of the drain hose. 

An optional condensate pump may be installed if a lift is required to 
dispose of the condensate. The condensate pump kit can be ordered 
direct from the factory. See item 27 on page 21.

3.4 Ducting

3.4A Installing Duct Collars

The Ultra-Aire is equipped with 8" and 6" round inlet collars and an 
8" round white exhaust collar. The 8" and 6" round inlet collars are 
designed with tabs that fold under the top of the Ultra-Aire. The 8" 
round white exhaust collar is attached to the Ultra-Aire by (4) screws.

To install the inlet collars:

 Insert the tabs of the collar into the hole in 

the top of the Ultra-Aire and fold the tabs up to attach to the Ultra-Aire. 

To install the exhaust collar:

 Bend the (4) tabs toward the inside of 

the collar 90°. Attach the collar to the Ultra-Aire cabinet using 1⁄2" 
long #8 sheet metal screws. DO NOT use screws longer than 1⁄2" to 
attach this collar or damage to the refrigeration system may result.

3.4B Ducting for Dehumidification

For the ideal installation, draw air from the central part of the home 
and return it to the isolated areas of the home like the bedrooms, 
den, utility room, or family room. The ductwork of the existing heating 
system can be used to supply air to the home. If the existing supply 
goes to isolated areas of the home, discharge the supply of the 
Ultra-Aire into the supply of the existing heating system. If the existing 
heating system incorporates a central supply, installation of a separate 
supply duct from the Ultra-Aire to each isolated area is recommended. 
DO NOT draw air directly from the kitchen, laundry, or basement. All 
flexible ducting connected to the Ultra-Aire should be UL listed.

The inlet of the Ultra-Aire is the 8" diameter hole on top of the unit. An 
8" round collar is supplied with the unit to attach to round duct. The 
duct may be permanently attached to the collar. A 6" round collar is 
provided with the unit to attach to the 6" hole in the top. The 6" collar 
should be capped if fresh make-up air is not desired. If fresh make-up 
air is desired see section 3.4C.

The outlet of the Ultra-Aire is located on the side of the unit. A second 
8" round collar is supplied with the unit and can be attached using the 
screws provided and the pre-punched holes in the cabinet side. 

A length of 10 feet or more of acoustical flex ducting on the outlet of 
the Ultra-Aire will reduce air noise from the blower. A length of flexible 
ducting on all Ultra-Aire duct connections is recommended to reduce 
noise and vibration transmitted to rigid ductwork in the structure. 

Ducting the Ultra-Aire as mentioned in sections 3.4A-3.4G requires 
consideration of the following points:

SAFETY PRECAUTIONS

2

3

Ultra-Aire 100V Installer’s & Owner’s Manual

Ultra-Aire 100V Installer’s & Owner’s Manual

Summary of Contents for Ultra-Aire DEH 3000

Page 1: ...fresh outdoor air may be ducted to the unit via a six inch round duct This provides fresh air to dilute pollutants and maintain high oxygen content in the air The amount of fresh air ventilation can...

Page 2: ...your Ultra Aire indoor air quality system Read and save these instructions The device is designed to be installed INDOORS IN A SPACE THAT IS PROTECTED FROM RAIN AND FLOODING Install the unit with spa...

Page 3: ...building supply plumbing and hardware stores It will slide tightly inside the end of the drain hose If more than one length of pipe is required they can be joined with a short piece cut from the end o...

Page 4: ...calling 1 800 533 7533 for recommendations regarding the use of higher flows with your specific application The outside air duct should be connected to the 6 round collar on top of the unit The 6 roun...

Page 5: ...ake sure none of the compressor tubes are pressed against the cabinet or front panel A length of 10 feet or more of acoustical flex ducting on the outlet of the Ultra Aire will reduce air noise from t...

Page 6: ...r of the timer face The reset button is the small recessed button with an R beneath it located below the 1 7 and h buttons Press the reset button in until the display disappears Release the reset butt...

Page 7: ...pot Test Method 52 76 This filter is much more efficient than the standard air filter and is able to catch much smaller particles that can aggravate allergies The high efficiency air filter is 4 inche...

Page 8: ...the unit to contact the red lead or the white lead from the unit or damage to the transformers will result Do not direct connect the white lead on the unit to the violet lead on the ventilation contro...

Page 9: ...Range Accuracy 10 95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H Major Operations n Digital control of Relative Humidity Digital Set Point n...

Page 10: ...n handling the high efficiency pleated paper filter Do not attempt to clean the high efficiency pleated paper filter It should be replaced when it becomes restrictive See Figure 7 7 Service CAUTION Se...

Page 11: ...or the correct charge weight and refrigerant type 7 5 Fan Replacement The centrifugal fan has a PSC motor and internal thermal overload protection If defective the complete assembly must be replaced 1...

Page 12: ...t carbon deposits the burn out occurred while the compressor was not rotating Contaminants are therefore largely confined to the compressor housing A single installation of liquid and suction line fil...

Page 13: ...gerant suction tube between the accumulator and the compressor It will automatically shut the compressor off if the low side refrigerant temperature drops due to excessive frost formation on the evapo...

Page 14: ...ULTRA AIR 100V ELECTRICAL SCHEMATIC 14 Ultra Aire 100V Installer s Owner s Manual...

Page 15: ...ULTRA AIRE 100V PICTORIAL ELECTRICAL DIAGRAM 15 Ultra Aire 100V Installer s Owner s Manual...

Page 16: ...anasonic 2R12S3R126A 6A 10 4022144 1 Compressor Overload TI MRA98706 673 not shown 11 4021396 1 Condenser Coil 12 4022445 1 Cord Wire Harness 13 4025087 1 Filter Drier 14 4021626 1 Hose Drain Pan 56 I...

Page 17: ...32 4024153 1 Cover for Items 28 29 not shown 33 4021495 1 Knob Black 25 shaft 34 4024150 1 Instructions Humidity Fan not shown 35 4024122 1 Instructions Ventilation Timer Humidity not shown 36 4025560...

Page 18: ...ULTRA AIRE 100V EXTERNAL INSULATION KIT 18 Ultra Aire 100V Installer s Owner s Manual...