5.2 Electrical Requirements

The Santa Fe Advance plugs into a common grounded outlet on a 
15-Amp circuit. While operating, it draws less than 7 amps @ 80°F, 
60% RH and less than 6 amps @ 75°F, 50% RH. Use of a ground 
fault circuit interrupter (GFCI) protected circuit is recommended. 
The unit should not be used in areas prone to flooding.

5.3 Condensate (Water) Removal

The Santa Fe Advance drains via a gravity system - it is not able 
to push condensate (water) uphill. The drain hose must run flat or 
downhill toward the drain location. Be sure the hose is not kinked 
or otherwise restricted so that water can pass through it. Improper 
hose installation may result in water leakage.

To increase the efficiency of the unit, position the hose to create a 
“trap” as shown in Figure 8. By creating a trap, it will hold a small 
amount of water. Position the trap on the hose approximately 12" to 
20" away from the unit. Check hose regularly to ensure it is clear and 
water is draining properly.

If floor drain is not easily accessible, a condensate pump kit with a 
20' hose is available. Refer to page 5 for ordering accessories.

6. Operation

6.1 Humidity Control Adjustment

The humidity control is an adjustable switch that turns the 
dehumidifier on and off. It turns on when the relative humidity of 
the air in which it is located rises to the dial set point. It turns off 
when the RH drops 5% below the set point.

Approximate Humidity Levels Per Setting
“Dry”

 

35% to 45% Relative Humidity

“Normal”

   45% to 55% Relative Humidity 

(Recommended for most applications)

“Humid”

  55% to 65% Relative Humidity

The dehumidifier will run continuously until the relative humidity 
(RH) is reduced to the humidity control dial setting. There is no 
benefit to setting the humidity control to “dry” in rooms under 65°; 
doing so will result in long periods of ineffective dehumidifier run 
time.

Quality humidity meters are available from Therma-Stor and are 
recommended to accurately monitor humidity levels. Please call 
1-800-533-7533 to order.

Once the dial has been set to the desired level of humidity control, 
the Santa Fe Advance will maintain the same percentage of relative 
humidity regardless of room temperature.

To turn the unit off, position the humidity dial to the far left and set 
fan control to “auto.”

6.2 Defrost Cycle

An automatic defrost thermostat is attached to the refrigerant 
tubes inside the unit. It will automatically shut the compressor 
off if excessive frost forms on the evaporator coil. The blower 
will continue to run, causing air to flow through the evaporator 
coil and melt the ice. When the ice has melted, the evaporator 
temperature will rise and the thermostat will automatically restart 
the compressor. During this process, cool air may be coming out of 
the unit.

6.3 Electrical Requirements

Turning the fan switch “FAN ON” will 
cause the unit’s internal blower to 
run continuously, whether the unit is 
dehumidifying or not. This function 
is desirable if the unit is used for air 
circulation or filtration. Turning the fan 
switch to “FAN AUTO” will cause the unit’s 

internal blower to run only while the unit is dehumidifying.

FAN

ON

FAN

AUTO

www.sylvane.com
1 (800) 934-9194

Summary of Contents for Santa-Fe Advance 4029800

Page 1: ... 533 7533 www santa fe products com sales thermastor com Designed For Basement and Crawlspace Dehumidification P N 4029800 INSTALLER S OWNER S MANUAL HVAC INSTALLER PLEASE LEAVE MANUAL FOR HOMEOWNER P N 4029800 Serial No ________________________ Install Date ___________ Sold by www sylvane com 1 800 934 9194 ...

Page 2: ... benefit from your Santa Fe dehumidifier Read and Save These Instructions WARNING This symbol means important instructions Failure to heed them can result in serious injury or death CAUTION This symbol means important instructions Failure to heed them can result in injury or material property damage 1 Intended Application The Santa Fe Advance is intended for installation in crawl spaces or basemen...

Page 3: ...d beinstalled directly in the area to be dehumidified Other considerations include 1 Providing access to a 115 VAC power outlet 8 power cord is provided 2 Locating near a floor or other suitable drain 8 drain hose included 3 Do not install the Santa Fe Advance with the intake or exhaust of the unit within 1 of a wall or other obstruction Do not place the unit where curtains or debris can be drawn ...

Page 4: ...etting Dry 35 to 45 Relative Humidity Normal 45 to 55 Relative Humidity Recommended for most applications Humid 55 to 65 Relative Humidity The dehumidifier will run continuously until the relative humidity RH is reduced to the humidity control dial setting There is no benefit to setting the humidity control to dry in rooms under 65 doing so will result in long periods of ineffective dehumidifier r...

Page 5: ...de Refer to Figure 11 Allow the filter to dry completely before reinstalling Reinstall the filters per the instructions below or on the tag located on the 1 4 pre filter CAUTION NOTE Failure to follow filter handling instructions may result in improper function of the dehumidifier and cause premature filter wear 7 3 Remove Filters 1 Gently remove the 1 4 pre filter by pulling on the tab attached t...

Page 6: ... fan switch AUTO and humidity control turned to ON 1 Defrost thermostat open ambient temperature too low 2 Loose connection in compressor circuit 3 Defective compressor overload 4 Defective compressor or compressor run capacitor Blower runs with fan switch AUTO but compressor cycles on off 1 Low ambient temperature and or humidity causing unit to cycle through defrost mode 2 Defrost thermostat def...

Page 7: ...nstalled If you need to order another set call 1 800 533 7533 and ask for Part Number 4026450 Step 2 Remove middle top cover screw located on the drain port side Do not discard this screw It will be used to attach the mounting bracket in the next step Step 3 Align mounting bracket of condensate pump with the dehumidifier screw hole Reinstall screw that was removed in step 2 Step 4 Remove the 7 hos...

Page 8: ...wner s Manual SANTA FE ADVANCE CONDENSATE PUMP INSTALLATION Step 5 Attach the 20 drain hose to the condensate pump and route it to a floor drain Plug in the condensate pump and the assembly is completed www sylvane com 1 800 934 9194 ...

Page 9: ... Lock the collar in position by bending the collar tabs outwards and flatten Step 4 All collar tabs are flattened Repeat steps 1 4 for top duct assembly Optional Accessory Duct Kit P N 4026055 Santa Fe Advance Duct Kit Assembly Instructions Do not drill any pilot holes into the plastic housing You may damage the internal components When installing screws be careful not to strip Lightly tighten scr...

Page 10: ...LY 1 Check sealing foam on the top duct assembly Ensure none has come loose 2 Place top duct assembly ensure the sealing foam makes contact around the plastic surfaces 3 Center the top duct assembly ensure the sealing foam makes contact around the plastic surfaces 4 Ensure the rear flange of the top duct assembly is seated flush against the back of the plastic housing See Figure 2 5 DO NOT DRILL P...

Page 11: ...codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim to Therma Stor such that Therma Stor receives such claim prior to the end of the applicable warranty period Therma Stor shall have no obligation hereunder with re...

Page 12: ...itted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2006 Therma Stor LLC All rights reserved PO Box 8680 Madison WI 53708 Phone 608 222 5301 Fax 608 222 1447 Web www thermastor com Email sales thermastor com www sylvane com 1 800 934 9194 ...

Reviews: