Ultra-Aire 135H Air Purifying Dehumidifier Owners Manual

5

• The word “CLOCK” appears at the top of the display during

the clock display, along with the day and time.

• The word “HUMIDITY” appears during the humidity display,

with the current setpoint on the left, and the ambient RH
on the right.

• The word “TEMP” appears as the unit displays the current

temperature.

• The fan status display is indicated by a capitol “F”. “OF”

indicates fan off status, “on” indicates fan on status.

• The damper display is indicated by a “d” with the same

on/off status indicators as the temperature.

• The ventilation program is displayed along the bottom of

the display during the clock, humidity, and temperature dis-
plays only when the damper operation is set to the pro-
grammed setting “Pr”.

5.2B Setting

During the set-up process, if you make a mistake, you can
always go back to adjust the settings. If you leave the control
alone and don’t touch any buttons for 10 seconds, the con-
trol will remember any changes made and return to “home
state.”

5.2C On/Off Setting

Press the “ON/OFF” button to turn the system on or off.
When the system is on, the green indicator will be lit. In the
off mode, the controller continues the regular display
sequence and indicates current time, temperature, and
relative humidity. It also displays the status of the fan and
damper as if the control were on, but the fan and damper will
not operate unless the control is on and the green indicator
is lit. Setup can be done with the control either on or off.

5.2D Setting Clock Time

1. Push “CLOCK” button. The hour display will flash, use the

“SET” + or – buttons to adjust hour. Notice the a.m./p.m.
display.

2. Push “CLOCK” button again. The minute display will flash.

Use the “+,–” buttons to adjust to the proper time.

3. Push “CLOCK” button again. The day display will flash. Use

the “+,–” buttons to select the proper day.

4. Push “CLOCK” button again. The AM/PM display will flash.

Verify AM/PM setting is correct.

5. Push “CLOCK” button again, or wait a few seconds for the

display to stop flashing. The time is now set.

5.2E Setting Relative Humidity Setpoint

The relative humidity setpoint operates the dehumidifier
function of the Ultra-Aire. It has no effect on any other func-
tion of the unit. The control senses the ambient relative
humidity of the space in which it is located. The ambient con-
dition is displayed on the right in the relative humidity display
sequence, under the word “HUMIDITY”. The current setpoint
is displayed on the left, under the word “SET”.

If the setpoint is equal to or greater than the current ambient
condition, the space does not need to be dried, so the dehu-
midifier function will be off. Example: Setpoint: 50% RH
Current condition 45% RH = Dehumidifier off, red “DEHU”
indicator not lit.

If the setpoint is less than the ambient condition, the
dehumidifier will be on, and the red “DEHU” indicator will be
lit. The space is more humid than the setpoint, so the con-
troller operates the dehumidifier to dry the space. Example:
Setpoint: 50% RH Current condition: 55% RH = Dehumidifier
on, red “DEHU” indicator lit.

To set the relative humidity setpoint, press the “HUM” button.
The display will show the “HUMIDITY” display, and the word
“SET” will flash. Use the “SET” + or – buttons to adjust the
relative humidity setpoint as desired. Therma-Stor Products
recommends relative humidity levels of 45% in the summer,
and lower levels in the winter. It is not recommended the
humidity setpoint be set below 35%. In order to dry the home
in the winter in a cold climate, use the ventilation function of
the system rather than the dehumidifier function.

On/Off

Program

Clock

Fan

Damper

Hum

Figure 2:

DEH 2000 User Panel

Figure 3:

DEH 2000 Clock DIsplay

Figure 4:

Fan Setting

Summary of Contents for FOCUS Ultra-Aire 135H

Page 1: ...midification The highly efficient Ultra Aire APD UA 135H dehumidifier utilizes refrigeration to cool the incoming air stream below its dew point This cooled and drier air is used to pre cool the incoming air stream resulting in up to a 200 percent increase in overall efficiency After the pre cooling stage the processed air is reheated by passing through the condenser coil The heat removed by the e...

Page 2: ... room The ductwork of the existing heating system can be used to supply air to the home 2 Registrations The Ultra Aire 135H P N 4025080 conforms to UL STD 1995 Certified to CAN CSA STD C22 2 No 236 3 Specifications Model UA 135H Air Purifying Dehumidifier Electrical 110 120 VAC 12 Amps 60 Hz grounded Capacity 135 pints day 80 F 60 RH Operating Temp 55 F min 100 F max Air Flow 355 CFM without exter...

Page 3: ...troller WITHOUT Fresh Air Refer to Sections 5 through Section 5 2G only 4 2 Humidity Control Adjustment Set the humidity control to the desired humidity level for the home Turning the knob clockwise results in a drier setting See the back of the control panel cover for set points The dehumidifier will run continuously until the relative humidity RH is reduced to the humidity control dial setting S...

Page 4: ... Now with the ventilation start time set press the I O button The word OFF should appear to the right of the time and the number 1 should remain in the lower right hand corner of the display The 1 and OFF signify the turn off time for the first program Set the turn off time using the 1 7 h and m buttons in the same way as described above and continue on to the second through sixth programs When se...

Page 5: ...r time 3 Push CLOCK button again The day display will flash Use the buttons to select the proper day 4 Push CLOCK button again The AM PM display will flash Verify AM PM setting is correct 5 Push CLOCK button again or wait a few seconds for the display to stop flashing The time is now set 5 2E Setting Relative Humidity Setpoint The relative humidity setpoint operates the dehumidifier function of th...

Page 6: ... will be open and the fan of the system will be operating in order to introduce fresh air into the space Use this mode for continuous fresh air ventilation The fan is always on when the damper is open When in off mode the damper will not open and the sys tem will not ventilate When in the program mode the control will operate the damper and fan ventilate according to the programmed ventilation sch...

Page 7: ...t exchange coils inside the unit could become clogged and require disassembly to clean Filter non compliance invalidates the product warranty 6 2 High Efficiency Air Filter An optional high efficiency pleated microglass paper filter is available for the UA 135H This filter is rated as 90 95 efficient by the ASHRAE Dust Spot test method 52 76 The high efficiency pleated microglass paper filter shou...

Page 8: ...mpeller fan does not run with ventilation timer activated 1 Defective ventilation timer 2 Time not correct on ventilation timer 3 Ventilation timer set to manual switched OFF 4 Defective fan switch Evaporator coil frosted continuously low dehumidifying capacity 1 Defrost thermostat loose or defective 2 Low refrigerant charge 3 Dirty air filter s or airflow restricted 4 Excessively restrictive duct...

Page 9: ...move the charge and weigh in the refrigerant quantity listed on the nameplate Operate the system to verify performance 7 7 Electric Ventilation Damper The electric ventilation damper is controlled by the ventilation timer The damper will open when the ventilation timer is activated to allow fresh air into the structure through the 6 diameter fresh air inlet duct The electric ventilation damper wil...

Page 10: ...care and proper return packaging LIMITATIONS AND EXCLUSIONS This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any Ultra Aire 135H part is repaired or replaced the new...

Page 11: ...n 3 4024539 DEH 2000 Digital Controller 4 4025287 Filter Box 5 4022220 Condensate Pump Kit External 6 4024377 Optional External Insulation Kit not shown 7 4024369 2 x20 x24 Filter not shown 8 4024370 4 x20 x24 Filter not shown 9 4020646 10 Backdraft Damper not shown 10 4025463 Stand Kit not shown Figure 1 Ventilation Timer Humidity Control Figure 2 Humidity Fan Control Figure 5 Condensate Pump Fig...

Page 12: ...22 1447 Web www thermastor com Email sales thermastor com Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2004 Therma Stor LLC All rights reserved ...