5.2F Fan Setting and Operation

Use the “FAN” button to adjust the fan operation. There are 3
choices for fan operation: “on”, “off” (denoted by “OF”), or
program (denoted by “Pr”). To set operation,
1. Press the “FAN” button. The display will indicate the cur-

rent fan setting.

2. Use the “SET” + or – buttons to adjust fan operation (“on”,

“OF”’ or “Pr”). Press the “FAN” button again or leave the
unit alone for 10 seconds to return to home state.

5.2G Fan On Fan Off Fan Program

The fan display reading in the normal display sequence does
not indicate the current fan setting, it indicates the current
fan status, and will always read either on or off. With the fan
in the “on” mode, the fan will run continuously. This does 
not effect the dehumidification functions of the system. In
other words, the system may or may not be ventilating or
dehumidifying while the fan is running. Common reasons 
for operating the fan continuously are continuous filtration
and air recirculation. With the fan in the “off” or “program”
mode, the fan will operate only when needed by other 
functions of the system. The fan will remain off unless the
system is dehumidifying and/or ventilating. The fan always
runs during dehumidification, it also always runs during 
ventilation. To completely turn the system off, use the
“ON/OFF” button as described earlier.

5.2H Damper Operation and Setting (Ventilation)

The damper setting controls the ventilation function of the
system. It has no control over the dehumidification function.
In order to provide ventilation, the damper must be open
(“on”) and the fan must be running. The controller takes 
care of these two functions automatically, so whenever the
damper is open (“on”), the fan is running.

This is true even if the fan has been set to the “off” mode.

The ventilation indicator “..” will be lit whenever the unit is
ventilating

There are three damper operation modes, “on”, “off”
(denoted by “OF”), and program (denoted by “”Pr”). With the
damper in the “on” mode, the damper will be open and the
fan of the system will be operating in order to introduce fresh
air into the space. Use this mode for continuous fresh air
ventilation. The fan is always on when the damper is open.
When in “off” mode, the damper will not open and the sys-
tem will not ventilate.

When in the “program” mode, the control will operate the
damper and fan (ventilate) according to the programmed
ventilation schedule (see the section referring to
programming the ventilation schedule).

To select damper operation:

1. Press the “DAMPER” button. The letter “d” will appear on

the display, along with the current mode setting.

2. Use the “SET” + or – buttons to adjust the fan setting to

the desired mode (“on”, “OF”, or “Pr”).

3. Press the “DAMPER” button again or leave the control

alone for 10 seconds to select the indicated damper mode
and return to the home state.

Damper On              Damper Off          Damper Program

5.2I Intermittent or Programmed Ventilation

With the damper in program mode (denoted by “Pr”
when setting the damper operation) the system will operate
the ventilation function according to the current ventilation
program. 

There are 4 programs available for ventilation Monday
through Friday. There are also 4 programs for Saturday and 4
programs for Sunday. No other choice of days is available.
Each program to be used has an “on event” called “START”
which brings the ventilation function on, and an “off event”
called “STOP” which turns the function off. Each START and
STOP must be entered in to the controller.

To set or adjust the ventilation program:

1. Press the “PROG” button two times. The display will indi-

cate “Program 1/start” at the bottom, and the hour display
will flash.

2. Use the “SET” + or – button to adjust the hour for the

Program 1 start time. Be sure to pay attention to the
am/pm setting.

3. Press the “PROG” button again. The display will indicate

“Program 1/start” at the bottom, and now the minute dis-
play will flash.

4. Use the “SET” + or – buttons to adjust to the desired

minute setting.

5. Press the “PROG” button again to move on to the

“Program 1/stop” event. The display will indicate “Program
1/stop” at the bottom, and the hour display will flash.

Figure 6:

Setting Damper

Figure 7:

Ventilation Programming

Figure 5:

Setting Fan

Summary of Contents for FOCUS Ultra-Aire 135H

Page 1: ...midification The highly efficient Ultra Aire APD UA 135H dehumidifier utilizes refrigeration to cool the incoming air stream below its dew point This cooled and drier air is used to pre cool the incoming air stream resulting in up to a 200 percent increase in overall efficiency After the pre cooling stage the processed air is reheated by passing through the condenser coil The heat removed by the e...

Page 2: ... room The ductwork of the existing heating system can be used to supply air to the home 2 Registrations The Ultra Aire 135H P N 4025080 conforms to UL STD 1995 Certified to CAN CSA STD C22 2 No 236 3 Specifications Model UA 135H Air Purifying Dehumidifier Electrical 110 120 VAC 12 Amps 60 Hz grounded Capacity 135 pints day 80 F 60 RH Operating Temp 55 F min 100 F max Air Flow 355 CFM without exter...

Page 3: ...troller WITHOUT Fresh Air Refer to Sections 5 through Section 5 2G only 4 2 Humidity Control Adjustment Set the humidity control to the desired humidity level for the home Turning the knob clockwise results in a drier setting See the back of the control panel cover for set points The dehumidifier will run continuously until the relative humidity RH is reduced to the humidity control dial setting S...

Page 4: ... Now with the ventilation start time set press the I O button The word OFF should appear to the right of the time and the number 1 should remain in the lower right hand corner of the display The 1 and OFF signify the turn off time for the first program Set the turn off time using the 1 7 h and m buttons in the same way as described above and continue on to the second through sixth programs When se...

Page 5: ...r time 3 Push CLOCK button again The day display will flash Use the buttons to select the proper day 4 Push CLOCK button again The AM PM display will flash Verify AM PM setting is correct 5 Push CLOCK button again or wait a few seconds for the display to stop flashing The time is now set 5 2E Setting Relative Humidity Setpoint The relative humidity setpoint operates the dehumidifier function of th...

Page 6: ... will be open and the fan of the system will be operating in order to introduce fresh air into the space Use this mode for continuous fresh air ventilation The fan is always on when the damper is open When in off mode the damper will not open and the sys tem will not ventilate When in the program mode the control will operate the damper and fan ventilate according to the programmed ventilation sch...

Page 7: ...t exchange coils inside the unit could become clogged and require disassembly to clean Filter non compliance invalidates the product warranty 6 2 High Efficiency Air Filter An optional high efficiency pleated microglass paper filter is available for the UA 135H This filter is rated as 90 95 efficient by the ASHRAE Dust Spot test method 52 76 The high efficiency pleated microglass paper filter shou...

Page 8: ...mpeller fan does not run with ventilation timer activated 1 Defective ventilation timer 2 Time not correct on ventilation timer 3 Ventilation timer set to manual switched OFF 4 Defective fan switch Evaporator coil frosted continuously low dehumidifying capacity 1 Defrost thermostat loose or defective 2 Low refrigerant charge 3 Dirty air filter s or airflow restricted 4 Excessively restrictive duct...

Page 9: ...move the charge and weigh in the refrigerant quantity listed on the nameplate Operate the system to verify performance 7 7 Electric Ventilation Damper The electric ventilation damper is controlled by the ventilation timer The damper will open when the ventilation timer is activated to allow fresh air into the structure through the 6 diameter fresh air inlet duct The electric ventilation damper wil...

Page 10: ...care and proper return packaging LIMITATIONS AND EXCLUSIONS This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any Ultra Aire 135H part is repaired or replaced the new...

Page 11: ...n 3 4024539 DEH 2000 Digital Controller 4 4025287 Filter Box 5 4022220 Condensate Pump Kit External 6 4024377 Optional External Insulation Kit not shown 7 4024369 2 x20 x24 Filter not shown 8 4024370 4 x20 x24 Filter not shown 9 4020646 10 Backdraft Damper not shown 10 4025463 Stand Kit not shown Figure 1 Ventilation Timer Humidity Control Figure 2 Humidity Fan Control Figure 5 Condensate Pump Fig...

Page 12: ...22 1447 Web www thermastor com Email sales thermastor com Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2004 Therma Stor LLC All rights reserved ...

Reviews: