3.3.20 Diagnostic Mode - Refrig. Test 

The display will communicate to the user the following 

information during a Refrigeration Test:
Inlet = Temperature and RH/Grains
Outlet = Temperature and RH/ Grains
Hours = Life hours only.
Evaporator Coil = Temperature
Countdown timer = 20 minutes
Once the 20 minute countdown timer has expired, the 

display will automatically advance to show the refrigeration 

test results. The display will communicate to the user either 

“Refrig. test passed” or “Refrig. test failed”.
Press the Next button to return to the first diagnostic test or 

press and hold the Next button for 3 seconds to return to the 

Dashboard.

 
3.4 Condensate Removal

The Phoenix Dry Max is equipped with an internal 

condensate pump to remove the water that is condensed 

during dehumidification. This allows the condensate to 

be pumped up to 20 feet with the attached hose. If the 

condensate must be pumped more than 20 feet above the 

unit, a second pump must be added to relay the condensate. 

The condensate pump automatically purges when the 

reservoir is full. Use the PURGE button to manually remove 

condensation.  

3.5 Ducting

A wire duct collar is supplied to allow 10” lay-flat duct to 

be attached to the Phoenix Dry Max outlet. Lay-flat plastic 

ducting is available; see section 6 Options and Accessories. 

To attach ducting to the wire duct collar, put the plastic duct 

end through the collar center and roll the duct end outward 

so that it overlaps the outside of the collar. The duct and 

collar may then be quickly attached to the Phoenix Dry Max 

by snapping the collar over the four exhaust tabs. 

3.6 Defrost Cycle

If the low side refrigerant temperature drops due to excessive 

frost formation on the evaporator coil and below the 

temperature set point, the thermistor activates the PLC and 

Status Light Indicator. The compressor is cycled off and on by 

the thermistor temperature measurement. The air mover will 

continue to run, causing air to flow through the evaporator 

coil and melt the ice when the compressor is off. When the 

air temperature and/or humidity increases, the evaporator 

temperature will rise and the thermistor will end the defrost 

cycle at the temperature set point

3.7 POWER Button

When the dehumidifier is plugged in it will enter stand-by 

mode.  

Press the 

button to turn the dehumidifier on. The unit 

will begin the Powering Up sequence and you will see this 

screen:

Press and hold the  

to turn the dehumidifier off. The 

dehumidifier will go through a powering-down cycle.  

6

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

POWER

POWER

Summary of Contents for 4036000

Page 1: ... Rugged roto molded housing resists dents and scratches Outlet Ducting 10 lay flat exhaust Pleated Media Air Filter MERV 10 Lighted cord Easy to determine power to the unit Specifications subject to change without notice TS 943 06 16 4201 Lien Rd Madison WI 53704 Phoenix Dry Max Part No 4036000 Patent Pending The Phoenix Dry Max is 6 smaller than the closest dehumidifier and yet it still has an in...

Page 2: ...sure all windows and doors are closed to the outside and seal off the wet area from any unaffected areas 3 1 Transporting The Phoenix Dry Max features a high impact roto molded housing which protects the unit It is recommended the units are properly secured for transport The Phoenix Dry Max must always be on its base when transported by vehicle It may be tipped upright to utilize its handle and ba...

Page 3: ...s the key to scroll through available values 3 8 4 Purging Press the button to purge the machine The display will communicate to the user that the machine is purging in the fourth line of the dashboard and show a 20 second countdown timer This will momentarily replace grain depression until the machine has finished purging The display will also communicate to the user that the machine is auto purg...

Page 4: ...on to toggle the Humidistat Fan mode from Always On to Auto Press the Next button to confirm selection and advance to the next screen Light Bar On The light bar colors and animations will persist while in Settings 3 3 10 Temperature Units Press the Set button to toggle the temperature units between F o and C o Press the Next button to confirm selection and advance to the next screen Light Bar On T...

Page 5: ...Else press the Next button to return to the Dashboard Light Bar On The light bar colors and animations will persist while in Settings 3 3 15 Diagnostic Mode Pump Press the Set button to toggle the Pump On Off Press the Next button to advance to the next screen 3 3 16 Diagnostic Mode Float Switch This display will communicate to the user the current status of the Float Switch Press the Next button ...

Page 6: ...ached to the Phoenix Dry Max outlet Lay flat plastic ducting is available see section 6 Options and Accessories To attach ducting to the wire duct collar put the plastic duct end through the collar center and roll the duct end outward so that it overlaps the outside of the collar The duct and collar may then be quickly attached to the Phoenix Dry Max by snapping the collar over the four exhaust ta...

Page 7: ...ut hose to drain completely 6 Replace air filter 5 Service WARNING Servicing the Phoenix Dry Max with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qualified service people should service this unit CAUTION Do not operate unit without the top cover in place CAUTION Do not operate...

Page 8: ...air filter or restricted air flow 4 Front housing is not sealed to rear housing Compressor runs with POWER button OFF 1 Defective control board 5 3 Air Mover The air movement is created by an impeller If defective the complete assembly must be replaced 1 Unplug power cord 2 Remove the exhaust and control board 3 Disconnect the impeller leads 4 Remove the impeller bracket 5 Remove the four screws h...

Page 9: ...racket to the bottom housing 5 Unscrew the float switch from the bracket 6 Replace the float switch from the bracket 6 Options Accessories 4037046 Air Filter Pleated 9 x 12 x 1 MERV 10 4024935 Lay Flat Duct 10 Round x 250 Roll To order contact Therma Stor LLC at 1 800 533 7533 7 Wiring Diagram COMP BLOWER CAPACITOR RED 3 YEL 2 BLK 4 RED 3 YEL 2 BRN 9 BLK 11 BRN BLK BLK 13 BLK 5 BLK BLOWER BLU GRN ...

Page 10: ...036848 Humidity Sensor 4034716 03 Evap Thermistor 4037041 Impeller 4037046 Filter 4036927 Filter Support 4036928 Exhaust Grill 4037048 Duct Ring 4036924 Control Board 4037038 Power Cord 4036935 Rubber Wheel 4036936 Wheel Axle 4036942 Handle Weldment 4036943 Handle Bushing RH 4036944 Handle Bushing LH 4036945 Handle Bracket RH 4036946 Handle Bracket LH 4033032 05 Capacitor 45 MFD 4035235 03 Capacit...

Page 11: ... The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix Dry Max Dehumidifier part is repa...