3. Specifications
Part Number:
4031470
Blower:
391 CFM @ 0.0" WG
363 CFM @ 0.2" WG
337 CFM @ 0.4" WG
Power:
920 Watts @ 80°F and 60% RH
Supply Voltage:
115 volt – 1phase – 60 Hz
Current Draw:
8.0 AMPS
Energy Factor:
3.5 L/kWh
Operating Temp.:
56°F Min., 95°F Max.
Sized for:
3600 Sq. Ft. - Typical
Minimum Performance at 80°F and 60% RH
Water Removal:
155 Pints/Day
Efficiency:
7.3 Pints/kWh
Air Filter:
MERV-11
Size:
16" x 20" x 2"
Power Cord:
10', 110-120 VAC, Ground
Drain Connection:
3/4" Threaded NPT
Dimensions
Unit
Shipping
Width:
20.25"
24"
Height:
21.75"
28.25"
Length:
38"
42"
Weight:
140 lbs
160 lbs
4. Installation
4.1 Location
The Santa Fe Max Dry Dual XT can be installed in a variety of
locations to meet the owner’s needs; other considerations
include:
1. Providing access to a 115 VAC power outlet (10'
power cord is provided).
2. Locating near a floor or other suitable drain (8'
drain hose included).
3. Mount 4" above drain.
4. Do not install the Santa Fe Max Dry Dual XT
with the exhaust of the unit within 1' of a wall or
obstruction. Do not place the unit near open water.
4.1A No Ducting (fig. 1)
The simplest installation is to place the Santa Fe Max Dry
Dual XT with no ducting. To ensure optimal performance, the
air inlet and the outlet of the unit must be at least 2' from
walls and other obstructions to air flow. Recirculation of
outlet air into inlet should be avoided as much as possible.
4.1B Ducted Return and Supply (fig. 2)
Dehumidification performance can be modified by adding an
return and/or supply duct to circulate air.
For optimal drying, use return duct to draw warm, moist air
from near the ceiling.
4.1C Remote Area, w/ Ducted Supply (fig. 3)
A simplified remote installation method than above uses
ducting between the Santa Fe Max Dry Dual XT discharge and
the humid room; the Santa Fe Max Dry Dual XT inlet draws air
from the room in which it’s located. This works well if there is
an adequate air flow path between the two rooms; e.g. high
Santa Fe Max Dry Dual XT OWNER’S AND INSTALLER’S MANUAL
3
Santa Fe Max Dry Dual XT Installer’s & Owner’s Manual
Input of
Humid Air
Out put of
Dehumidified Air
Front View
Input of
Humid Air
Front View
Output of Dehumidified Air
Front View
4031470