3. Specifications

Part Number:

 4031470

Blower:

 

 391 CFM @ 0.0" WG 
363 CFM @ 0.2" WG 
337 CFM @ 0.4" WG

Power:

 

920 Watts @ 80°F and 60% RH

Supply Voltage:

 

115 volt – 1phase – 60 Hz

Current Draw:

 

8.0 AMPS

Energy Factor: 

 

3.5 L/kWh

Operating Temp.:

  56°F Min., 95°F Max.

Sized for: 

3600 Sq. Ft. - Typical

Minimum Performance at 80°F and 60% RH

Water Removal: 

155 Pints/Day

Efficiency: 

7.3 Pints/kWh

Air Filter:

 

MERV-11

Size: 

16" x 20" x 2"

Power Cord:

 

10', 110-120 VAC, Ground

Drain Connection:

  

3/4" Threaded NPT

Dimensions 

Unit

 

Shipping

Width: 

20.25" 

24"

Height: 

21.75" 

28.25"

Length: 

38" 

42"

Weight: 

140 lbs 

160 lbs

4. Installation

4.1 Location

The Santa Fe Max Dry Dual XT can be installed in a variety of  
locations to meet the owner’s needs; other considerations 
include: 

1.  Providing access to a 115 VAC power outlet  (10' 

power cord is provided).

2.  Locating near a floor or other suitable drain (8' 

drain hose included).

3.  Mount 4" above drain.

4.  Do not install the Santa Fe Max Dry Dual XT 

with the exhaust of the unit within 1' of a wall or 
obstruction. Do not place the unit near open water.

4.1A No Ducting (fig. 1) 

The simplest installation is to place the Santa Fe Max Dry 
Dual XT with no ducting. To ensure optimal performance, the 
air inlet and the outlet of the unit must be at least 2'  from 
walls and other obstructions to air flow. Recirculation of 
outlet air into inlet should be avoided as much as possible.

4.1B Ducted Return and Supply (fig. 2) 

Dehumidification performance can be modified by adding an 
return and/or supply duct to circulate air.

For optimal drying, use return duct to draw warm, moist air 
from near the ceiling.

 
4.1C Remote Area, w/ Ducted Supply (fig. 3) 

A simplified remote installation method than above uses 
ducting between the Santa Fe Max Dry Dual XT discharge and 
the humid room; the Santa Fe Max Dry Dual XT inlet draws air 
from the room in which it’s located. This works well if there is 
an adequate air flow path between the two rooms; e.g. high 

Santa Fe Max Dry Dual XT OWNER’S AND INSTALLER’S MANUAL

3

Santa Fe Max Dry Dual XT Installer’s & Owner’s Manual

Input of 

Humid Air

Out put of

Dehumidified Air 

Front View

Input of

Humid Air 

Front View

Output of Dehumidified Air 

Front View

4031470

Summary of Contents for 4031470

Page 1: ...oducts com Free standing Moisture Control for Large Areas n High capacity n High efficiency n Environmentally friendly n Patent pending dual air distribution INSTALLER S OWNER S MANUAL P N 4031470 Ser...

Page 2: ...o not sit or stand on the unit or use as a shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or...

Page 3: ...all or obstruction Do not place the unit near open water 4 1A No Ducting fig 1 The simplest installation is to place the Santa Fe Max Dry Dual XT with no ducting To ensure optimal performance the air...

Page 4: ...ng CAUTION For proper drainage the unit must be mounted so the drain outlet is at least 4 above the floor drain and must be fully supported under the base 4 3 Condensate Water Removal Condensate drain...

Page 5: ...ships with a standard MERV 11 efficient pleated fabric filter This should be checked every six months The pleated fabric filter can generally be vacuumed clean several times before needing replacemen...

Page 6: ...but compressor cycles on off 1 Low ambient temperature and or humidity causing unit to cycle through defrost mode 2 Defrost thermostat defective 3 Defective compressor overload 4 Defective compressor...

Page 7: ...e factory mounted humidity control on the cabinet of the dehumidifier and allows you to accurately sense the humidity in an area other than the one where the dehumidifier is located Santa Fe Max Dry D...

Page 8: ...er any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Res...

Page 9: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680...

Reviews: