9. Press MODE to change Thermometer Probe 2. Press MEAT so BEEF is displayed.

10. Press TASTE so MEDIUM WELL is displayed and 160  F will be shown as the 
      TEMP SET.

º

11. You may take the receiver up to 300 feet away from the outdoor grill. Go indoors 
      if desired.

12. When the temperature of first piece of steak reaches 150  F MEDIUM, the 
      receiver will beep and the LCD backlight will be turned on.

º

13. Press any button to turn off the alert. 

14. Take the first piece of steak out of grill.

15. When the temperature of second piece of steak reaches 160  F MEDIUM WELL, 
      the receiver will beep and the LCD backlight will be turned on.

º

16. Press any button to turn off the alert.

17. Turn off grill. Remove the probe sensors from both steaks. Always wear a heat 
      resistant glove to touch the stainless steel probe sensor or wire during or just 
      after cooking. Do not touch with bare hands.

18. Clean the stainless steel probe and dry thoroughly after each and every use. 

19. Turn off the transmitter and receiver.

Using the Timer

Count down

1. Press the MODE button to select the TIMER mode. The timer 00:00 with a small 
    icon TIMER will be shown in the upper part of the display. 

2. Press MEAT to switch between Hour: Minute timer to a minute' second” timer 
    and back.

3. Press     or     to adjust timer setting. Press and hold     or     to adjust setting at  
    a faster pace. Press ST/SP/CLEAR to confirm the setting. The maximum  
    countdown timer setting is 99 hours and 59 minutes.

4. Press and hold ST/SP/CLEAR to clear the setting back to 00:00

5. After setting, press ST/SP/CLEAR to start the timer. TIMER     will blink indicating 
    the countdown timer is running.

6. To pause the countdown process, press the ST/SP/CLEAR button. The TIMER  

        becomes solid. Press the ST/SP/CLEAR button to continue the timer.

7. When countdown timer reaches 00:00, an alarm will sound and backlight will be 
    on for one minute.  

Note:

 When the timer counts down below 1 hour 1:00, the display will automatically 

change to 59'59” to indicate, 59 minutes 59 seconds. The seconds will be shown 
counting down then. When the countdown reaches 0'00” the timer starts counting 
up and it will beep for 60 seconds. Press any button to stop the timer. 

1. Press the MODE button to select the TIMER mode, The timer 00:00 with a small 
    icon TIMER will be shown in the upper part of the display. If the timer setting is 
    not 00:00, press and hold ST/SP/CLEAR to clear the setting to 00:00.

2. Press the ST/SP/CLEAR button to start count up. The TIMER     will blink 
    indicating count up timer is running. The maximum count up that can be reached 
    is 99 hours and 59 minutes.

3. To stop the count up process, press the ST/SP/CLEAR button. The TIMER  
    becomes solid.

4. Press and hold ST/SP/CLEAR to clear the setting back to 00:00.

5. When count up timer reaches 59 minutes and 59 seconds, it will automatically 
    change to Hour: Minute display format. 

Helpful Hints

If the receiver and / or the transmitter display LLL or HHH instead of the probe 
temperature, wait for probe to reach room temperature. If LLL or HHH is still 
displayed or you get a false temperature, squeeze the probe jacks harder into 
the transmitter and twist them back and forth so they make good contact. If the 
problem still persists, it is likely the internal probe wire has shorted out either 
through moisture or heat damage.

Do not immerse the probe in water while cleaning.

Do not allow the probe or probe wire to come into contact with flames.

Within the warranty period return defective probe to address below along with 
a return address and we will send you a replacement probe at no charge.

Count up

-9-

-8-

Summary of Contents for TP-22

Page 1: ...You will now be able to remotely monitor the temperature of cooking food and the temperature inside your grill oven or smoker from anywhere in your home Components 1 One receiver unit 2 One transmitte...

Page 2: ...ur Minute or Second setting Press and hold for 2 seconds the hours minutes or seconds will decrease at faster pace 4 ST SP CLEAR When setting the timer press to confirm the setting When the timer sett...

Page 3: ...r and the units are ready for use However in some unusual cases the transmitter and receiver are no longer paired then you may need to re synchronize them by following the below steps a Insert the sta...

Page 4: ...o the preset USDA ranges 7 6 3 Once the temperature of meat reaches the preset doneness level the receiver will beep and the LCD backlight will be turned on Press any button to stop the beep Measure o...

Page 5: ...IMER becomes solid Press the ST SP CLEAR button to continue the timer 7 When countdown timer reaches 00 00 an alarm will sound and backlight will be on for one minute Note When the timer counts down b...

Page 6: ...pe the transmitter and receiver with damp cloth Do not immerse either in water FCC Compliance Information to user Warning Changes or modifications to this unit not expressly approved by the party resp...

Page 7: ...ghts which vary from state to state CUSTOMER SERVICE Telephone 1 877 515 7797 USA CANADA only Email service buythermopro com Hours Weekdays 8 00 AM 6 00 PM EST MEAT Rare Med Rare Medium Med Well Well...

Page 8: ...comptage progressif Plage de temp rature de la sonde 32 F 572 F 0 C 300 C Tol rance de temp rature de la lecture interne des aliments 1 8 F 1 0 C Compartiment de la batterie Supporte 2 piles AAA Atta...

Page 9: ...ype Probe2 Temp Setting Probe 2 Temp Reading Timer mode Taste level Probe 1 Temp Setting Probe 1 Temp Reading Heure Minute ou le mode Minute et Second LAMB FISH et OVEN En mode minuterie appuyez pour...

Page 10: ...e pas tre en mesure de recevoir la transmission du transmetteur Si cela se produit pendant plus de 4 minutes l appareil vous alertera que le signal est perdu En appuyant sur une touche quelconque le r...

Page 11: ...nde 2 dans le deuxi me morceau de steak Supposons que vous voulez faire cuire le premier morceau de steak saignant et la deuxi me pi ce a point 4 Placez le fil du capteur de la sonde afin qu ils ne so...

Page 12: ...e le r glage 00 00 2 Appuyez sur le bouton ST SP CLEAR pour commencer le comptage progressif La TIMER clignotera indiquant que le comptage progressif de la minuterie est en marche Le d compte jusqu un...

Page 13: ...pas les plonger dans l eau Conformit FCC Information pour l utilisateur Attention En cas de changements ou de modifications qui ne sont pas express ment approuv s par la partie responsable celle ci p...

Page 14: ...us tes domicili SERVICE CLIENTS T l phone 1 877 515 7797 Uniquement aux tats Unis et Canada Courriel service buythermopro com Heures d ouverture Jours de la semaine 8 00 AM 6 00 PM heure locale Mesure...

Page 15: ...installation If this equipment does cause harmful interference to radio ortelevision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the...

Reviews: