TROUBLE SHOOTING
POOR FLOW OF WATER
•
CHECK FOR ADEQUATE WATER PRESSURE
•
CHECK FOR DEBRIS IN THE WATER INLETS
•
CHECK FOR LIME SCALE BUILD UP. REMOVE THE MIXER /
THERMOSTAT CONTROL AND DESCALE IF NEEDED (IN HARD
WATER AREAS THIS MAY BE REQUIRED MORE OFTEN)
POOR TEMPERATURE CONTROL
TOO MUCH HOT OR COLD WATER
•
CHECK WATER SUPPLY IS PROPERLY BALANCED
•
CHECK FOR LIME SCALE BUILD UP. REMOVE THE MIXER /
THERMOSTAT CONTROL AND DESCALE IF NEEDED (IN HARD WATER
AREAS THIS MAY BE REQUIRED MORE OFTEN)
•
CHECK WATER SUPPLY FOR BLOCKAGES, CLEAN FILTERS, CHECK
THAT INLETS ARE INSTALLED CORRECT I.E. HOT ON LEFT COLD ON
RIGHT.
•
INSERTS ‘
A
’ WHERE NOT USED WHEN SCREWING ADAPTERS IN TO
BREECH.
•
IF INCOMING PRESSURE IS ABOVE OR BELOW STATED GUIDELINES.
Page 13
ONLY HOT OR COLD WATER FROM MIXER OUTLET
•
CHECK WATER SUPPLY FOR BLOCKAGES, CLEAN FILTERS, CHECK
THAT INLETS ARE INSTALLED CORRECT I.E. HOT ON LEFT COLD ON
RIGHT.
•
REMOVE THERMOSTATIC CARTRIDGE AND CHECK CONDITION I.E.
SCALE OR DEBRIS. CLEAN FILTERS.
THE SHOWER VALVE WILL BE DAMAGED IF
INSTALLED WHERE WATER PRESSURE EXCEEDS OR
CAN EXCEED 500kPa. THE VALVE WILL CONTINUE TO
DRIP AND WILL BE BEYOND REPAIR AND WILL VOID
WARRANTY