background image

ADJUST FEED SYSTEM 

This system is for service technicians only. It is used to alter the amount the chlorine or 
acid fed into the pool over a given period of time. Adjustment of these settings can result in 
incorrect operation for the pool size and alteration should not be attempted unless advised 
by 

Theralux Advanced Mineral Pool Systems.

Dis/Enable Shutdowns

 

Turns any protective shutdowns on/off.  For example if the pH goes below 5.9 

Chlor Dose Pump ON/OFF 

If the unit is being used to control a salt chlorinator it is also possible to run a chlorine dose 
pump as a back-up. The dose pump can be turned on/off from this menu. 

Auto Mode and Full Manual (MAN/AUTO) Menu 

Full Manual Mode (FMM) 

FMM is used when an external timer is controlling the unit. 
If FMM is selected, the pump system is either turned ON or OFF whenever power is 
supplied to the Unit.  The Unit

’s timer is effectively disabled. 

The LCD will indicate that the Unit 

is in manual mode with either the message “Man ON” or 

“Man OFF”.

AutoMode 

When running in Auto Mode, the Unit has up to 4 adjustable Filter Cycles. Factory default 
settings have Filter Cycle 1 and Filter Cycle 2 enabled.  
Filter Cycle 1 is always enabled. The other 3 Filter Cycles can be enabled or disabled (in 
order) allowing you to increase or decrease running times quickly without adjusting the 
Filter Cycle ON/OFF times 

– simply add or remove cycles. 

When you first turn on the Unit in AutoMode, the pump will be off even if the time is in the 
middle of a programmed Filter Cycle.  The Unit will wait for the next available ON-time to 
start the pump and the rest of the system.  
If there is an extended power failure, the Unit will continue to keep time for a number of 
days. During this time the pump ON/OFF-times will still be checked. When power is 
restored, the system will wake up and turn the pump ON if it is during a Filter Cycle.  

Automatic Operation 

In AutoMode, Line2 of the LCD will display whether the Pump is ON or OFF and the next 
OFF or ON time.   

Manual Operation while In AutoMode 

You can override the AutoMode settings manually by pressing either the ON button (to turn 
ON if the system is off automatically) or OFF to stop the pump if it is on automatically. The 
Unit is still in AutoMode and will respond to the next AutoOFF/ON time. 