Cycle program
Cyclically recurring time
functions within the scope of a timer,
e.g.: slow flashing indicator, water treatment,
advertisement lighting
The symbol flashes when the cycle program
is active.
Effect of the cycle program:
The clocking and pause times can be set separa-
tely. The settable times are max. 99 minutes and
59 seconds. The cycle program has the effect that
between two programmed times, day of week
start and day of week finish, the cycle program
is active. The cycle program always begins with a
switch on.
16
memory locations are available to you.
Example cycle start:
Monday 7.30 h ON
Example cycle finish:
Friday 16.30 h OFF
Viewing the cycle times:
Possible in the menu
Cycle
only!
N.B.:
If two cycle times are programmed in which the start and
finish times overlap, it is always the cycle time that starts first
that is executed.
Example:
Cycle time
1,
programmed from: Mo to Thu
Cycle time
2,
programmed from: Tue to Fri
Only cycle time
1
is effective, cycle time
2
is
not
accepted.
duration
pause
Select by pressing the
key
Cycle.
Store your selection by pressing the
key.
Set cycle
start
by pressing the keys
or
.
Store your selection by pressing the
key.
Set cycle
duration
(Min./sec.) by pressing the keys
or
.
Store your selection by pressing the
key.
Set cycle
pause
(Min./sec.) by pressing the keys
or
.
Store your selection by pressing the
key.
Set cycle
finish
by pressing the keys
or
.
Store your selection by pressing the
key.
Brightness variations at
lighting installations may
arise in the cycling mode.
In this case actions to reduce
these effects have to be
taken (for example reduc-
tion of the load or extension
of the cycle time).
More than 5 switching ope-
rations per minute are not
admissible without additio-
nal EMC interference mea-
sures.