background image

 

Contact

 

 

TC 649 C manual 

 

36 

 

 

8

 

Contact 

 

Theben AG 

Hohenbergstr. 32 
72401 Haigerloch 
GERMANY 
Phone +49 7474 692-0 

Fax +49 7474 692-150 
 

Hotline 

Phone +49 7474 692-369 
[email protected] 

Addresses, telephone numbers, etc.  

www.theben.de/en

 

 

Summary of Contents for 6490430

Page 1: ...2021 06 30_310547 Manual for TC 649 C Version 1...

Page 2: ...he IP address statically 13 4 Theben cloud TC 649 C remote control 15 4 1 Setting up a Theben cloud account 15 4 2 Connecting the TC 649 C to the Theben cloud 15 4 3 Managing the TC 649 C via the Theb...

Page 3: ...installed in the network via an integrated web server The control box is integrated into the company network The control box must have an Internet connection so that it can be addressed via the Theben...

Page 4: ...ol box can be called up on a desktop PC or a mobile end device such as a tablet or smartphone The following browsers operating systems are supported Browsers o Google Chrome from version 69 onwards Op...

Page 5: ...single device without any external software Administration via web interface The TC 649 C can be easily configured via the web Updating firmware Firmware can be easily updated via the web interface 1...

Page 6: ...nection to the NTP server Relay Off All relays are switched off On One or more relays are switched on PWR TLS Off The TC 649 C is switched off Flashing The TC 649 C is switched on 1 4 2 Front The sock...

Page 7: ...Start up TC 649 C manual 7 2 Start up Please refer to the enclosed installation and operating instructions for information on how to connect the device and carry out initial operation...

Page 8: ...Make sure the cabling is correct Connect the cables in accordance with the following sections There are three ways of carrying out the start up process for the TC 649 C 1 Start up via the hostname se...

Page 9: ...er in the following format http serial number You will find the serial number on the device The serial number will always start with DTHE 5 If accessing the device via the serial number does not work...

Page 10: ...use the user interface of your router to display all connected devices and their IP addresses Please refer to your router manual to see exactly how to do this If accessing the device via the serial n...

Page 11: ...twork socket on your PC 5 Plug the other end of network cable 2 into the left hand Service socket on the TC 649 C 6 Connect the TC 649 C to the power supply 7 Open the web browser Google Chrome 8 Open...

Page 12: ...ser enter the IP address that you read out in point 12 in the following format http IPaddress 17 The login screen will appear Your TC 649 C is connected to your network The start up process is now com...

Page 13: ...ug network cable 2 into the network socket on your PC 5 Plug the other end of network cable 2 into the left hand Service socket on the TC 649 C 6 Connect the TC 649 C to the power supply 7 Open the we...

Page 14: ...ace of the TC 649 C 16 Now connect your PC to your home network again via WiFi or LAN 17 Open the web browser Google Chrome 18 In the address field in the browser enter the IP address that you assigne...

Page 15: ...cloud theben de 4 2 Connecting the TC 649 C to the Theben cloud If the TC 649 C has not been connected to the Theben cloud it will not appear online under https cloud theben de To connect your TC 649...

Page 16: ...49 C via the Theben cloud Open https cloud theben de and log in Via the Gateways menu item open the list of devices that are linked to your account TC 649 C 4 3 1 Management and remote control Select...

Page 17: ...ill need to invite a user first Further information can be found below 4 4 User administration in the Theben cloud Open https cloud theben de and log in Via the Users menu item open the list of device...

Page 18: ...rs You can only delete users if you are registered as the owner Under Installations select the TC 649 C whose user you wish to delete Under Users you will see all users of your TC 649 C Select the use...

Page 19: ...main way to navigate around the user interface is via the menu bar at the top of the screen You can access all the TC 649 C settings via this navigation bar Menu items marked with a contain sub menu i...

Page 20: ...u item If the main menu item contains sub menu items a drop down menu will open You can then click on the sub menu item you want 6 1 Start Detailed device information is displayed on the start page Th...

Page 21: ...49 C in this menu Please note that all changes only affect the right network interface Ethernet 6 2 1 1 DHCP static To change the network interface from DHCP to static Untick the Use DHCP field Enter...

Page 22: ...ou untick the box you can change the time again The control box is briefly unavailable after settings have been saved Changes to the network settings may result in loss of contact with the control box...

Page 23: ...Save 6 2 3 Update firmware You can run a device update in this menu You can run the device update either online Internet connection required or offline not on mobile devices A firmware update can only...

Page 24: ...reparable damage to the device Offline update Drag and drop the firmware package provided by Theben AG into the dashed field Then click on Start firmware update Press Yes to confirm and carry out the...

Page 25: ...assword you will be automatically logged out and redirected to the login page Log in using your new password 6 2 5 Theben cloud In this menu you can connect your TC 649 C to the Theben cloud See the C...

Page 26: ...is switched off and cannot be changed via the programmed switching times PERM ON The channel is switched on and cannot be changed via the programmed switching times AUTO The channel is switched accor...

Page 27: ...Controls and menu TC 649 C manual 27 6 3 2 ot2 download You can transfer the ot2 file from the OBELISK software to the control box here You can only download the ot2 file via the desktop browser...

Page 28: ...ttps play google com store apps details id de theben OBELISKtop3 hl de iOS https apps apple com de app obelisk top3 id1273748982 Loading ot2 file switching times on to device with Windows Create an ot...

Page 29: ...Loading ot2 file switching times on to device with iOS or Android Create an ot2 file using the OBELISK top3 app 1 Create a new project 2 Select TC 649 C 3 Create switch program 4 Send switch program t...

Page 30: ...y The astro functionality for the individual channels must be stored in the OBELISK software The astro offset can be changed to values within the range 120 minutes to 120 minutes Changing the astro of...

Page 31: ...the Log out button in the top right hand corner of the screen You will then be redirected to the login page 6 6 Password forgotten If you have forgotten your password click on Forgotten password on th...

Page 32: ...log in again using the user name admin and the password admin 6 7 Switching language You have the option of setting a different interface language on the TC 649 C To do this click on the language in t...

Page 33: ...cted to the supply voltage Check the network connection between the TC 649 C and the PC or router Check the network configuration of your TC 649 C and or your PC or router 7 2 2 How can I tell if my T...

Page 34: ...250 V AC cos 1 Switching of any phase is permitted Switching SELV is only permitted if both switching channels in each case top or bottom switch SELV Minimum load 5 V 1 mA Switch contact contact Frequ...

Page 35: ...ishes a connection between two network systems IP address Addresses a device in the network so that it can be reached DHCP Dynamic Host Configuration Protocol Makes it possible to assign a network con...

Page 36: ...49 C manual 36 8 Contact Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Phone 49 7474 692 0 Fax 49 7474 692 150 Hotline Phone 49 7474 692 369 hotline theben de Addresses telephone numbers etc www...

Reviews: