Fitting & Balancing the Cartridge
Step 1; Rough Balance
Three plates are fitted to the arm as shipped. This is fine for the
majority of cartridges.
But if your cartridge is light (<6g) you will probably only need
one plate.
If you cartridge is heavy (>8.5g) it is likely you will need three
or more plates.
Extra plates can be ordered for really heavy cartridges (>11g)
The smaller square edged plate can be used to give an
intermediate step and on its own for light cartridges.
Step 2;
Attaching the cartridge
Where possible use the supplied Aluminium M2.5 screws unless;
Your cartridge has tapped holes
(use screws supplied with cartridge).
You need more mass.
Either for a very light weight cartridge or a very low compliance cartridge.
Step 3; Attach the Leads
to the cartridge
Left (Black)
Right (Red)
.
Blue
=Left Ground
White=Left + / Hot
Red
=Right + / Hot
Green
=Right Ground
A
WARNING
; Be careful, cartridges
are easily damaged.
Use your stylus guard.
Screws should be done up
firmly but not over-tightened.
We cannot be liable for
damage to the cartridge either
in installation or use.
www.thewandtonearm.com
© Feb 2017 design
build
listen Ltd. v17
Plates
1
2
3
Cartridge Spacer Option;
You have been provided with a small metal plate with two holes.
This may be put between the cartridge and the arm in three circumstances;
If the cartridge is too light to balance
If the cartridge suit a heavier arm (This spacer adds 2g)
eg; Denon DL103
If the cartridge is short or touches the carbon fibre when installed.
NOTE; Vertical Tracking Angle may need to be higher than indicated in section B4
A 5g weight is available as an option, just ask.