![THE SHOWER LAB VR01S100 Manual Download Page 9](http://html1.mh-extra.com/html/the-shower-lab/vr01s100/vr01s100_manual_1100500009.webp)
02/2021 V 1.0
VIEW 01
03/13
Carefully position the Glass Panel using
the measurements below:
x = End Cap (3mm) + Lip Distance
Ensure there is adequate glass in the
Wall Profile. (6mm is recommended)
Mark/scribe the Underframe at the top
face of the Glass Panel.
If required, mark/scribe the vertical
Wall Profile also to the end face of the
Glass Panel.
DO NOT trim the Profiles at this stage.
Carefully lift the Glass Panel out and
put to one side. Remove the Wall
Profile, Wall Profile Soft Seal,
Underframe Gasket, and Underframe
Profile and set to one side.
WARNING
The glass is heavy and may
damage the
fl
oor or underframe if
handled incorrectly. It is advisable
to use a suitable non-slip
protective mat or piece of carpet.
Never rest the glass across the
underframe as this may cause
damage.
6mm min
Wall Pro
fi
le
Lip
Distance
x
Glass Panel
Underframe
09
10
11