background image

Please read these instructions thoroughly before use. Failure to follow instructions may 

result in equipment damage or failure, losses, injury or death.

 DANGER: 

To avoid possible electric shock:
  •  If the power cord has been damaged, DO NOT operate, the ClearSolution™ G2 Filter should  

be replaced. 

  •  Prior to installation, inspect the quartz sleeve and UVC bulb to ensure there was no damage 

during transportation. 

  • Close supervision is necessary when the unit is used by or near children.

 WARNING: 

To reduce the risk of electric shock:
  •  Connect only to a properly grounded receptacle, which is serviced by a Ground Fault Circuit 

Interrupter and never remove the ground pin from the plug. 

  •  Provide a “drip loop” for the power cord. This is a loop in the cord below the level of the 

receptacle or plug that prevents water from traveling along the cord in the direction of  

the receptacle. 

  •  ALWAYS unplug the ClearSolution™ G2 Filter from power source when it is not in use, and 

before installing, removing or servicing the ClearSolution™ G2 Filter components.

  •  If an extension cord is necessary, a cord with a proper rating should be used. A cord may 

overheat if the cord is rated for less amperes or watts than the unit rating.

  • DO NOT immerse the ClearSolution™ G2 Filter plug in water or attempt to use a wet plug. 
  •  The ClearSolution™ G2 Filter is NOT suitable for use in swimming pools, swimming ponds, or 

other situations where bodily contact is made with the water.

 CAUTION: 

To reduce the risk of equipment damage or failure:
  •  ALWAYS keep the ClearSolution™ G2 Filter completely submerged during operation for  

proper cooling.

  • DO NOT place ClearSolution™ G2 Filter near flammable or other dangerous materials or objects.
  • DO NOT use the ClearSolution™ G2 Filter with fluids other than water.
  • ALWAYS unplug the unit if there is no water running through it to prevent over heating.
  •  DO NOT operate during freezing conditions. Drain the ClearSolution™ G2 Filter and store in a 

protected location. 

  •  DO NOT operate the ClearSolution™ G2 Filter with a pump larger than the pump indicated 

by the unit specifications.  Operating with a pump larger than recommended can reduce the 

UVC’s effectiveness or cause damage to the UVC and filter and will NOT be covered under 
warranty.

  

The Pond Guy® is not responsible for equipment damage or failure, losses, injury or death 

resulting from failure to follow safety precautions, misuse or abuse of equipment.

thepondguy.com  |  866-POND-HELP (766-3435)  

2

Summary of Contents for ClearSolution G2

Page 1: ...urClearSolution G2Filter 5 6 MaintainingYourClearSolution G2Filter 7 10 Troubleshooting 11 ReplacementParts 12 13 WarrantyInformation 16 Table of Contents For Model ClearSolution G2 700 Item 130060 Cl...

Page 2: ...A cord may overheat if the cord is rated for less amperes or watts than the unit rating DO NOT immerse the ClearSolution G2 Filter plug in water or attempt to use a wet plug The ClearSolution G2 Filte...

Page 3: ...ClearSolution G2 700 120V 60 Hz 7Watts 1 2 250 GPH 700 Gallons ClearSolution G2 1250 120V 60 Hz 9Watts 1 2 3 4 580 GPH 1 250 Gallons MODEL Max Head Height Operating Depth DIMENSIONS POWER CORD LENGTH...

Page 4: ...and organic matter as it passes through the system The final step is to pass water through the powerful UV Clarifier This ensures the pond water stays crystal clear all season The filtered water can n...

Page 5: ...rn Bell Pattern Watch a video of the ClearSolution G2 Filter installation online www thepondguy com clearsolutionG2 Step 2 Connect Fountain Assembly to the Filter Screw the assembly onto the ClearSolu...

Page 6: ...daptor to add a spitter or other decorative feature or turn the diverter valve to force all water to the fountain nozzle Step 4 Place Filter in Pond Place the filter on a flat surface towards the midd...

Page 7: ...placement UV Bulb Replacement Filter Media Pads Replacement Quartz Sleeve if yours is cracked or damaged Step 1 Unplug UV and Pump Unplug the UV and pump disconnect any plumbing and remove the unit fr...

Page 8: ...ebris from the filter base with water Step 7 Remove UV Housing Press and hold the clip on the UV and twist the UV housing in the direction indicated to remove Step 8 Remove Compression Nut Remove the...

Page 9: ...y reduce the effectiveness of the UV Clarifier If your quartz sleeve is cracked or damaged it must be replaced Note Condensation may form on the quartz sleeve This cannot be avoided and does not impai...

Page 10: ...be rinsed throughout the season anytime water flow is reduced Avoid using chlorinated tap water or detergents which will strip the media of beneficial bacteria Step 18 Reinstall Filter Reconnect the...

Page 11: ...UVC bulb if it has not been replaced in the past year even if it is operational Check that the quartz sleeve is clean Verify that the proper amount of water is flowing through the filter See recommen...

Page 12: ...E Top Cover 130064 130075 F Filter Pad Set 130065 130066 G UV Bulb 110408 110306 H Quartz Sleeve 130063 130074 I Quartz Sleeve Hardware Kit 130043 130043 J Quartz Sleeve O Ring 130069 130069 K UV Hous...

Page 13: ...A B C D A E F N J K M L I H G REPLACEMENT PARTS MODEL 1250 15425 Chets Way Armada MI 48005 13...

Page 14: ...NOTES thepondguy com 866 POND HELP 766 3435 14...

Page 15: ...NOTES 15425 Chets Way Armada MI 48005 15...

Page 16: ...e UVC bulb filter media o rings and fitting set are wearable items and are not covered by this warranty Abuse or misuse of this product or power cord alterations void all warranty Please call for a Re...

Reviews: