background image

A. System Components in the Box:
1.

  Fountain Pump with Quick Disconnect, float mount ring and  

Classic Spray Pattern (installed)

2.

 Float - Blue

3. 

Power Cord

4. 

Control Panel

5. 

Crown & Rocket Spray Pattern (interchangeable)

6. 

Geyser Spray Pattern (interchangeable)

B. Prepping the AquaStream™ for Installation:

1)

  Ensure you have power close to your pond. If you don’t, we recommend to ALWAYS use a 

licensed electrician to properly run power down to the pond.

2)

 Mount the Control Panel in a fixed position next to the power source.

3)

 

Choose Your Spray Pattern (Fig. 3)

 

 

a)

  The AquaStream™ comes packaged with the Classic spray pattern installed. However, 

the AquaStream™ includes two additional spray patterns (Geyser and Crown & Rocket).  
Pick the one that best suits you or your special event.

 

b)

  To change a pattern, simply unscrew the nozzle nut, replace the pattern and reinstall the 

nozzle nut.

4) 

 

Assembling the Unit (Fig. 4)

 

a)

 Lay the float flat on the ground with The Pond Guy

®

 logo facing up.

 

b)

 Place the fountain pump assembly into the center of the float. 

 

c)

  Lift the float straight up and ensure that the fountain pump lead power cord passes 

through the center hole. Gently lay the fountain to one side.

 

d)

 Securely attach the power cord to the fountain pump lead quick disconnect.

 

e)

 Attach the power cord strain relief to the loop underneath the float mount ring. (Fig. 2) 

 

f)

   Attach a mooring cable (not included) for each of the two loops underneath the float  

mount ring. (Fig. 2)

 

3. Setup & Installation

Classic

Geyser

Crown & Rocket

Fig. 3

Fig. 4

Unscrew Nozzle Nut to 
change Patterns

Mooring Kit Options:

#651052 – 

 150’ Mooring Kit

#651054 – 

 250’ Mooring Kit

* Mooring Kit Not Included with Fountain

TM

• 2 stakes

• 2 carabiners

• 4 cable clamps

• 150’ or 250’ black vinyl  

coated galvanized cable  
(Mooring Line)

Recommended Mooring Kit

Power Cord

Loop

Loop

Underwater Disconnect

Carabiner

AquaStream™ Floating Fountain

Control 

Panel

Mooring Stake

Fig. 1

Fig. 2

 Mooring Line  

(Vinyl Coated Galvanized Wire)

3A

ENGLISH

Summary of Contents for AquaStream AC05

Page 1: ...TM AquaStream HP Floating Fountain Model AS05 5 6A 120V 60Hz Owner s Manual...

Page 2: ...VER lift or drag the fountain by the power cord Handles are provided for lifting and carrying During freezing temperatures remove fountain and store inside If installing the fountain from a boat or ra...

Page 3: ...ing the Unit Fig 4 a Lay the float flat on the ground with The Pond Guy logo facing up b Place the fountain pump assembly into the center of the float c Lift the float straight up and ensure that the...

Page 4: ...ter Removal Storage 1 Remove the fountain from the pond before ice begins to form 2 This is the perfect time to clean or power wash any debris on the unit before storing 3 It is recommended to store t...

Page 5: ...CORRECTION Intake plugged Clean intake Voltage not high enough for starting Make sure voltage at receptacle is 120V 5 Fountain impeller stuck Remove fountain clean replace impeller IF LIGHTS TURN ON...

Page 6: ...651339 Float 12 651340 Control Panel 13 Power Cord Options 651378 100 feet 16 3 651379 150 feet 14 3 651380 200 feet 14 3 651415 250 feet 12 3 14 651356 Power Cord End Cap Male 15 651060 Strain Relie...

Page 7: ...ente por el cable de alimentaci n Los mangos se proporcionan para levantar y transportar Durante las temperaturas de congelaci n retire la fuente y almacenar en su interior Si la instalaci n de la fue...

Page 8: ...la flotaci n en el suelo con el logotipo The Pond Guy hacia arriba b Coloque el conjunto de bomba de la fuente en el centro del flotador c Levante el flotador hacia arriba y aseg rese de que el cable...

Page 9: ...camente de escombros las algas y o malezas acu ticas B Remoci n de Invierno y Almacenamiento 1 Retire la fuente del estanque antes de que el hielo comienza a formarse 2 Este es el momento perfecto par...

Page 10: ...Clean Tensi n no lo suficientemente altos para el arranque Aseg rese de que la tensi n en el recept culo es de 120V 5 Fuente impulsor atascado Retire fuente limpio reemplazar el impulsor Si las luces...

Page 11: ...2 651340 Panel de control 13 Opciones Cable de alimentaci n 651378 100 pies 16 3 651379 150 pies 14 3 651380 200 pies 14 3 651415 250 pies 12 3 14 651356 Tapa del extremo del cable de alimentaci n mas...

Page 12: ...n Des poign es sont pr vues pour le levage et le transport Pendant des temp ratures glaciales retirez fontaine et stocker l int rieur Si vous installez la fontaine d un bateau ou d un radeau toujours...

Page 13: ...er l crou de buse 4 Montage de l unit Fig 4 a Poser le plat du flotteur sur le terrain avec The Pond Guy logo vers le haut b Placez l ensemble de pompe de la fontaine au centre du flotteur c Soulever...

Page 14: ...iques B D m nagements et garde Hiver 1 Retirer la fontaine de l tang avant que la glace commence se former 2 Ce est le moment id al pour nettoyer ou de pouvoir laver les d bris de l appareil avant de...

Page 15: ...ev pour un d marrage Assurez vous que la tension au r ceptacle est 120V 5 Fontaine roue bloqu Retirer fontaine remplacer propre roue Si les lumi res allument et se teignent par intermittence QUESTION...

Page 16: ...12 651340 Panneau de contr le 13 Les options du cordon d alimentation 651378 100 pieds 16 3 651379 150 pieds 14 3 651380 200 pieds 14 3 651415 250 pieds 12 3 14 651356 Cordon embout m le 15 651060 D...

Page 17: ...Notes...

Page 18: ...Notes...

Page 19: ...believed to be covered under warranty it will be necessary to notify The Pond Guy Inc for assistance If it is concluded that there may be a defect which may be covered under war ranty you will be iss...

Page 20: ...Geyser Pattern Optional Double Arch Pattern Optional Single Arch Pattern For Information on Optional Spray Patterns Visit Us Online at thepondguy com aquastream 15425 Chets Way Armada MI 48005 866 PO...

Reviews: