background image

Page 7 of 9 

 

ACTIVATING THE WARMING CYCLE  
From remote

 

Press and hold the remote button down 

for 2 seconds to activate 

warming to the preset 

warming time 
 

NOTE

o

  While the unit is warming, the remote will pulse a soft orange glow so you know it 

is warming. 

o

  When warming cycle is complete, the remote will glow orange  for 10 minutes 

and the base unit LCD screen will display “00” and will be back lit in soft orange 

  To shut off the lights (LCD screen and remote) prior to the auto shut off 

time, press the power button for 2 seconds. 

 

 

NOTE

: After 

attempting to activate the warming cycle by remote,

 the remote is 

programed to alert you to potential issues.  

If you get such a response from the remote, 

go to the base unit for problem solving.  Potential solutions: 

 

Remote battery level low 

LCD Screen 

- flashing battery icon

 

 

Remote

 - When pushed to activate warming cycle, the warming cycle will 

start and the remote will flashes orange/blue lights for 10 seconds then to 
pulsing orange (then solid orange when warming is complete).  While the 
unit is in standby mode, the remote will flash orange every 10 minutes 

No water in water reservoir 

 

LCD Screen

 - shows H2O

 

Remote

 

– will flash alternating blue and orange lights  

Remote is out of range from the base unit 

LCD Screen

 - normal setting allowed into standby

 

Remote

 - no lights when button is pushed

 

The base unit is not in standby mode 

LCD Screen

 - blank 

Remote

 - no lights when button is pushed 

Expired Batteries 

LCD Screen

 - flashing low battery icon  

Remote

 - no lights when button is pushed 

Base unit and remote are not paired 

LCD Screen

 - normal setting allowed into standby 

Remote

 - no lights when button is pushed 

 

From base unit

 

Press the power button once to activate warming to the preset warming time 
 

NOTE:   

  The LCD screen on the base unit will show time remaining in the warming cycle.  

The screen will pulse a soft glow during warming cycle.   

  When complete the LCD screen will be a soft solid glow for 10 minutes 

 

WARNING 

 

ALWAYS swirl bottle contents/stir food well and test temperature of 
contents before giving bottle to child.  

 

 

ALWAYS use the lift-out basket when warming or sterilizing.

   

  When warming cycle has completed, the base unit will contain steam:   

o

  Use caution when removing lid and/or removing bottle from the warmer. 

 

o

  The lid may contain condensation, use caution removing/placing lid on 

furniture 

To cancel warming cycle: 

Push down on the power button for 3 seconds to cancel warming.  It is not 
recommended to reheat formula or breastmilk - either serve or dispose of bottle 
contents after canceling warming cycle.

 

 

 

 

 

Summary of Contents for Remote Bottle Warmer

Page 1: ...reservoir Lift out basket Freezer bottles 2 Control panel Warming time reference drawer Remote button o Questions Let s talk help thefirstyears com USA Canada 800 704 8697 Reference image from the CMF CMF lists extra parts and unneeded info use list above Exploded view of the control panel with callouts pointing to Up arrow button Down arrow button LCD Screen Low battery indicator Error indicator ...

Page 2: ...ake offer or recommend any accessory attachments for this unit The use of any kind of accessory attachments may cause injury NOTE additional freezer bottles can be purchased at thefirstyears com 12 For household use only Do not use outdoors 13 Do not place on or near a hot gas or electric burner 14 Do not move unit when hot or contains hot liquids 15 Do not use this unit for anything other than it...

Page 3: ... unit as well as inside warming chamber with a damp cloth or sponge using mild liquid soap Wipe with clean water Air dry DO NOT IMMERSE BOTTLE WARMER IN WATER Do not use scouring pads solvents or abrasive cleaners as they could damage the unit Remove the pop out divider behind water reservoir for better access Warming chamber Mineral deposits usually white in color may form on the inner surfaces o...

Page 4: ... the fill line Reference image from the CMF fill line is circled in orange oval FILLING THE WATER RESERVOIR 1 Remove the reservoir from the base unit 2 Remove Unscrew the cap 3 Fill with clean water to the fill line 4 Replace Screw on the cap 5 Place the reservoir into the base unit NOTE The unit will automatically dispense enough water needed for the set warming time Line drawing showing water go...

Page 5: ...ired coming out of the package However should the connection between the base unit and remote be broken it will need to be paired again To pair the remote to the base unit 1 Plug in the base unit and make sure there are charged batteries in the remote 2 With the base unit OFF press and hold UP and DOWN button for 5 seconds 3 LCD will display P when P appears release the UP DOWN buttons 4 Press the...

Page 6: ...Turn the unit ON by pressing the power button down for 2 seconds 2 Using the up down buttons set the desired warming time a Use the provided chart to determine the recommended warming time NOTE The recommended warming times are not exact durations Adjust the warming times as desired b For initial use the LCD screen will read 0 00 After using the unit for a warming cycle the unit will display the w...

Page 7: ...g blue and orange lights Remote is out of range from the base unit LCD Screen normal setting allowed into standby Remote no lights when button is pushed The base unit is not in standby mode LCD Screen blank Remote no lights when button is pushed Expired Batteries LCD Screen flashing low battery icon Remote no lights when button is pushed Base unit and remote are not paired LCD Screen normal settin...

Page 8: ...use battery leakage or improper storage or maintenance of the products Disclaimer of Other Warranties THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES However to the extent applicable law does not permit disclaimers of certain implied warranties such warranties are limited to the warranty period identified above Some states and countries do not allo...

Page 9: ... the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly a...