background image

1022409-9-

A

SERVICE KIT INSTRUCTIONS

Heater Switch Replacement

1022408, 1033675

Heater

Pressure Switch

Earth Ground

Ground Wire

Earth

Ground

Split Ring Nut

Gasket Or

O-Ring

J4 Plug

Junction Box

(4 kW Heater Only)

Tee Fitting

Heater Replacement

WARNING

:

Risk of electrical shock.

If the whirlpool is equipped

with a 1.5 kW heater, there is one electrical circuit. If the whirlpool is

equipped with a 4 kW heater, two electrical circuits are used. Make sure

that both electrical circuits are turned off before servicing the whirlpool.

NOTE:

See “Replacing Tee Fitting” if the pressure switch tee fitting is to

be replaced during whirlpool circulation harness repairs. If you are not

replacing the tee fitting in the whirlpool harness, the old and new

pressure switch housings will need to be disassembled and the new

pressure switch transferred to the old housing.

1.

With the bath drained, turn all power to the unit off.

2.

Disconnect the ground wire from the heater.

3.

Disconnect the heater control cord at the J4 plug on the control.

4.

Heaters rated at 4 kW have a separate junction box to supply heater

power. Open the junction and mark the wiring before disconnecting

the 4 kW heater.

5.

Remove the heater from the suction line of the whirlpool harness.

Save the O-rings/gaskets for installation of the replacement heater.

Summary of Contents for 1022408

Page 1: ...ing if the pressure switch tee fitting is to be replaced during whirlpool circulation harness repairs If you are not replacing the tee fitting in the whirlpool harness the old and new pressure switch...

Page 2: ...the switch 9 Remove the old pressure switch from the housing by turning the switch counterclockwise 10 Remove the top half of the new housing to expose the new pressure switch Remove the new pressure...

Page 3: ...tion Box Wiring Heater Replacement continued 14 Connect the 4 kW heater wiring in the heater junction box as shown in the above diagram 15 Connect the heater control cord at the J4 plug on the control...

Page 4: ...ing in the whirlpool harness 2 Cut the tee fitting from the harness 3 Replace with a standard 1 X 1 X 1 tee fitting with couplings and piping as needed Orient the tee above horizontal to help ensure t...

Page 5: ...interrupteur pression du raccord en T doit tre remplac l occasion de la r paration de la tuyauterie de circulation de la baignoire hydromassage Si vous ne remplacez pas le raccord en T de la tuyauter...

Page 6: ...l interrupteur pression 9 Retirez le vieil interrupteur pression de son logement en le tournant vers la gauche 10 Retirez la partie sup rieure du nouveau logement pour exposer l interrupteur pression...

Page 7: ...nuation 14 Connectez le c blage du chauffage de 4 kW dans la bo te de jonction du chauffage comme indiqu sur le plan 15 Connectez le c ble de contr le du chauffage au niveau de sa prise de contr le J4...

Page 8: ...ssage 2 Coupez le raccord en T de la tuyauterie 3 Remplacez le avec un raccord en T standard de 1 X 1 X 1 ainsi que les raccord et tuyau comme d sir Orientez le T ci dessus horizontalement tout en gar...

Page 9: ...de la conexi n en T si la conexi n en T del interruptor de presi n se debe reemplazar durante la reparaci n de las tuber as de circulaci n en la ba era de hidromasaje Si no va a reemplazar la conexi n...

Page 10: ...cables del interruptor 9 Retire el interruptor de presi n antiguo del alojamiento girando el interruptor a la izquierda 10 Retire la parte superior del alojamiento nuevo para dejar al descubierto el...

Page 11: ...ontinuaci n 14 Conecte el cableado en la caja de empalmes del calentador de 4kW tal y como se ilustra en el diagrama de arriba 15 Conecte el cable de control del calentador en el punto de conexi n J4...

Page 12: ...T de las tuber as 3 Reempl cela con una conexi n en T est ndar de 1 X 1 X 1 con racores y tubos seg n sea necesario Oriente la T hacia arriba para ayudar a garantizar que las tuber as de circulaci n...

Reviews: