background image

Pump & Pipe
Installation Instructions

INSTALLATION B:
CONNECTION TO AN EXISTING DISCHARGE
PIPE (Diagram B)

Depending on your installation requirements, PVC
pipe lengths will vary.  Cut the pipes and assemble
them as shown in photo #7.  

Do not cement them

together  until  you  are  sure  they  are  cut  to  the
correct  lengths.

It  is  important  to  keep  the

discharge  pipes  on  both  pumps  parallel  to  each
other, so that the pumps remain flat on the floor
of the sump.  More detailed instructions follow.

Unplug the main AC pump when installing the
backup pump to avoid electric shock.  Failure
to do so could cause serious injury or death.

1. Cut a piece of 1½” rigid PVC pipe long enough

to reach from the bottom of the sump pit to
one  (1)  foot  above  the  floor.    Prime  and
cement it to the 1½” pipe adapter, then screw
the adapter into the pump.

2. Install  a  check  valve  on  the  top  of  the  PVC

pipe  attached  to  the  Basement  Watchdog
pump.  Make sure it is installed with the arrow
pointing up or it will not prevent the backflow
of water.

3. When  a  check  valve  is  used,  a  1/8”  hole

must be drilled in the PVC pipe above the
Basement Watchdog pump.  Make sure it is
above  the  water  line  and  below  the  check
valve.  Drill the hole at a 45º angle toward
the bottom of the sump to avoid splashing

water outside the sump pit.  If a 1/8” hole
is not drilled in the pipe above the pump,
an  air  lock  may  prevent  the  pump  from
operating.

4. If  there  is  no  check  valve  on  the  discharge

pipe  of  the  main  AC  pump,  one  must  be
installed at this time.  Cut the discharge pipe
approximately  one  (1)  foot  above  the  floor.
Install  a  check  valve  on  the  top  of  the  pipe
and  tighten  the  bottom  hose  clamp.    Now
prime  and  cement  a  small  piece  of  1½”  PVC
pipe to the bottom of a “Y” connector.  Prime
and cement the top of the “Y” assembly to the
discharge pipe with the “Y” extension facing
down toward the backup pump.  Now connect
the bottom of the assembly to the check valve
and tighten the hose clamp.

Failure to install a check valve between the “Y”
connector and the main AC pump will cause the
backup system to not operate properly. A 1/8”
hole must also be drilled in the PVC pipe above
the main AC pump.

5. Secure the pump wire so that the plug on the

end  will  not  fall  into  the  sump.    Attach  the
wire to the pipe with a piece of tape.

6. Place the pump with the PVC pipe attachment

on the bottom of the sump floor next to the
main AC pump. 

The pumps should not touch

each  other.

Do  not  mount  the  pump  to  any

existing  pipes;  it  should  be  placed  on  the
floor of the sump.  A brick should be placed
under  the  pump  if  there  are  rocks  or  other
debris  on  the  sump  floor  that  may  clog  the
pump.

7. Connect a piece of 1½” PVC pipe above

the  check  valve  of  the  Basement
Watchdog  pump,  and  attach  a  45°
elbow  to  that  pipe.    Extend  another
piece  of  pipe  to  reach  from  the  45°
elbow  to  the  “Y”  connector  on  the
other pipe.

8. Prime and cement all pipe connections

securely  to  prevent  leaking,  and
tighten all the hose clamps.

Page 5

 

 

PUMP

WIRE

PIPE

 ADAPTER

FLOOR

JOIST

MAIN 

1/8” HOLE

A
BRICKS

C PUMP

RIGID

1-1/2"

PVC PIPE

CHECK
VALVE

1/8" HOLE

45º ELBOW

"Y" CONNECTOR

CHECK
VALVE

DRAIN   TILE

SLOPE

PIPE

DOWN

BASEMENT

WATCHDOG

PUMP

Diagram B

4

5

6

7

2

3

CAUTION

!

DANGER

1

CAUTION

Summary of Contents for big dog +

Page 1: ...to outside 4 Connection to existing discharge 5 Direct discharge for narrow sumps 6 Connection to existing discharge for narrow sumps 7 Battery Instructions 8 Control Unit Connections Positioning the...

Page 2: ...any repairs at the following address Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 4205 BATTERY PREPARATION Sulfuric acid can cause blindness or severe burns Avoid contact with skin eyes or...

Page 3: ...dog Emergency Standby Battery 24EP6 of BW 24F with this system It will not run the pump as long as the Big Standby Battery The internal construction of some wet cell batteries may not be compatible wi...

Page 4: ...main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so that the battery backup pump and the main pump do not touch each other Select the installation...

Page 5: ...ia the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outsi...

Page 6: ...his time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1 PVC pipe...

Page 7: ...e details of each installation will vary Using sound plumbing practices route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capa...

Page 8: ...Basement Watchdog pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pipe above...

Page 9: ...before use the battery will always be fresh Use 1 265 specific gravity battery acid to fill the battery It is available where you purchased the battery NOTE Basement Watchdog batteries now come in two...

Page 10: ...be charged 70 80 30 minutes after adding the acid The system will then finish charging the battery During this time the alarm may sound When you fill the battery for the FIRST time it will be the ONL...

Page 11: ...sensor into the cap b If the top of the battery has two large caps place the fluid sensor in the hole molded on the top of the battery It is located in the second cell from the positive post and the l...

Page 12: ...ically reset itself after 24 hours The warning light will stay on 1 Battery fluid low Risk of electrical shock or battery explosion which can cause serious injury or death Wear eye protection Work in...

Page 13: ...epartment for further instructions The phone number is 800 991 0466 option 3 If the battery alarm goes on while the pump is running and the power is out you will have a minimum of one 1 hour of contin...

Page 14: ...front of the control panel for one 1 second REPLACING THE BATTERY Risk of electrical shock or battery explosion which can cause serious injury or death Wear eye protection Work in a well ventilated ar...

Page 15: ...k to see if the wires in the fuse are intact To remove the barrel fuse push in and turn counter clockwise Replace the fuse by pushing it in and turning clockwise If the wires are burned and broken rep...

Page 16: ...uctions on page 1 REFER TO PHOTOS AT LEFT AND ABOVE 1 Unplug the Basement Watchdog control unit from the wall outlet 2 Remove the cover of the battery box by pushing in the tabs on the front and back...

Page 17: ...crew marked common Turn the screw a few turns to lock in the wire If the security system requires a closing of a contact to activate the alarm secure the other wire in the terminal hole labeled N O no...

Page 18: ...pump will run off the battery Press and hold the reset button to silence the alarm for 24 hours Try another outlet replace the fuse or reset the circuit breaker Make sure the power cord is plugged in...

Page 19: ...one float fail to operate the second float automatically activates the pump The protective cage prevents debris or other wires from interfering with the movement of the float It can be used to replace...

Page 20: ...the address listed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the co...

Reviews: