background image

Introduction

The  Basement  Watchdog  Big  Dog  backup  sump
pump  is  designed  as  an  emergency  backup
system to support your main AC sump pump, and
it will automatically begin pumping any time the
float switch is activated by rising water.  

If your main AC pump breaks or is unable to keep
up  with  all  the  incoming  water,  the  Basement
Watchdog  pump  is  capable  of  running  without
discharging the battery as long as the AC power
is on.  As soon as the AC power is interrupted,
the  battery  takes  over.  Should  any  malfunction
or  emergency  occur  that  involves  the  sump
pump,  the  battery,  or  the  AC  power,  the
Basement Watchdog system will sound an alarm.
A light on the display panel of the control unit
will  indicate  the  cause  of  the  alarm  and  the
corrective action.

For added reliability, the float switch has, not one,
but two floats. Should one float fail to operate, the
second float automatically activates the pump.

To  extend  the  battery  run  time,  two  batteries
may  be  connected  to  the  Basement  Watchdog
Big Dog system by purchasing a second battery
and acid pack, as well as a set of battery jumper
cables.  Jumper cables specifically designed for

this  use  are  available  from  the  manufacturer,
Glentronics, Inc.

The Basement Watchdog Sump Pump 
System includes:

• A  control  unit  with  a  dual  float  switch,  a

battery fluid level sensor, battery cables, a
5 amp AC fuse, and a 25 amp DC fuse

• A  plastic  wire  tie  for  mounting  the  float

switch

• A pump with a 1½” pipe adapter
• A battery box
• A battery cap with a hole to accommodate

the fluid sensor

  

You will also need to supply:

• A Basement Watchdog Big Standby Battery

(30HDC140S  or  BW-30F)  or  Basement
Watchdog Maintenance Free (AGM) Standby
Battery (BW-27AGM). 

DO NOT 

use an automotive battery with this

system.

DO NOT 

use a Basement Watchdog Emergency

Standby Battery (24EP6 of BW-24F) with this
system.  It will not run the pump as long as
the Big Standby Battery.
The  internal  construction  of  some  wet  cell
batteries  may  not  be  compatible  with  this

system.    Glentronics  can  not  guarantee  the
compatibility  of  other  brands  of  batteries.
The  use  of  a  Basement  Watchdog  battery  is
HIGHLY recommended.

• 1½” rigid PVC pipe and fittings
• PVC primer and cement
• A union with hose clamps or a “Y” connector

and two (2) check valves, depending on the
installation method you use

• A surge protector (recommended)
• Six  (6)  quarts  of  1.265  specific  gravity

battery acid (only if using a 30HDC140S or
BW-30F battery)

For narrow sump pits you will need
some additional parts:

• An “L” bracket at least six (6) inches long

(preferably one that will not rust)

• Two (2) stainless steel hose clamps
• One  (1)  stainless  steel  screw  (#8-32  x

3/4”), a matching washer & nut 

To connect two batteries you will need:

• Two (2) batteries of the same age, type and

capacity (so they will have equal power)

• Another battery box
• Two (2) acid packs to fill the dry batteries
• A  set  of  battery  cables  with  rings  on  both

ends to connect the two batteries together
(available from Glentronics, Inc.)

Use of a Basement
Watchdog Klunkless
Check Valve™ will
provide quieter
operation.  
(See back cover for
more information.)

Replacement Part Numbers

Pump  . . . . . . . . . . . . . . . . . . . . . . .1011003
Float switch assembly   . . . . . . . . . . .1020009
Fluid sensor assembly  . . . . . . . . . . . .1014001
Pipe adapter  . . . . . . . . . . . . . . . . . .1120002
Battery box  . . . . . . . . . . . . . . . . . . .1113003
Battery cap with hole  . . . . . . . . . . . .1125000
Battery jumper cable for 2 batteries  . . . . . .PJC

Call 800-991-0466, option #3 to order parts.

System Specifications

Power supply requirements  . . . . . .115 volts AC
Pumping capacity  . . . . . . . . . .3500 GPH @ 0’
Pumping capacity  . . . . . . . . .2200 GPH @ 10’
Pump dimensions w/elbow  . . . . . .7

5

8

” H x 9”W

Pump housing & strainer  . . . . . .non-corrosive, 

will not rust

Pump  . . . .can run dry for short periods of time
Float switch  . . . . . . . . . .independent, can be 

set at any level

Page 2

Control Unit

Battery Box

Cap

Wire Tie

Float Switch

Pipe

Adapter

Pump

Battery

Wires

Fluid Sensor

Summary of Contents for big dog +

Page 1: ...to outside 4 Connection to existing discharge 5 Direct discharge for narrow sumps 6 Connection to existing discharge for narrow sumps 7 Battery Instructions 8 Control Unit Connections Positioning the...

Page 2: ...any repairs at the following address Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 4205 BATTERY PREPARATION Sulfuric acid can cause blindness or severe burns Avoid contact with skin eyes or...

Page 3: ...dog Emergency Standby Battery 24EP6 of BW 24F with this system It will not run the pump as long as the Big Standby Battery The internal construction of some wet cell batteries may not be compatible wi...

Page 4: ...main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so that the battery backup pump and the main pump do not touch each other Select the installation...

Page 5: ...ia the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outsi...

Page 6: ...his time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1 PVC pipe...

Page 7: ...e details of each installation will vary Using sound plumbing practices route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capa...

Page 8: ...Basement Watchdog pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pipe above...

Page 9: ...before use the battery will always be fresh Use 1 265 specific gravity battery acid to fill the battery It is available where you purchased the battery NOTE Basement Watchdog batteries now come in two...

Page 10: ...be charged 70 80 30 minutes after adding the acid The system will then finish charging the battery During this time the alarm may sound When you fill the battery for the FIRST time it will be the ONL...

Page 11: ...sensor into the cap b If the top of the battery has two large caps place the fluid sensor in the hole molded on the top of the battery It is located in the second cell from the positive post and the l...

Page 12: ...ically reset itself after 24 hours The warning light will stay on 1 Battery fluid low Risk of electrical shock or battery explosion which can cause serious injury or death Wear eye protection Work in...

Page 13: ...epartment for further instructions The phone number is 800 991 0466 option 3 If the battery alarm goes on while the pump is running and the power is out you will have a minimum of one 1 hour of contin...

Page 14: ...front of the control panel for one 1 second REPLACING THE BATTERY Risk of electrical shock or battery explosion which can cause serious injury or death Wear eye protection Work in a well ventilated ar...

Page 15: ...k to see if the wires in the fuse are intact To remove the barrel fuse push in and turn counter clockwise Replace the fuse by pushing it in and turning clockwise If the wires are burned and broken rep...

Page 16: ...uctions on page 1 REFER TO PHOTOS AT LEFT AND ABOVE 1 Unplug the Basement Watchdog control unit from the wall outlet 2 Remove the cover of the battery box by pushing in the tabs on the front and back...

Page 17: ...crew marked common Turn the screw a few turns to lock in the wire If the security system requires a closing of a contact to activate the alarm secure the other wire in the terminal hole labeled N O no...

Page 18: ...pump will run off the battery Press and hold the reset button to silence the alarm for 24 hours Try another outlet replace the fuse or reset the circuit breaker Make sure the power cord is plugged in...

Page 19: ...one float fail to operate the second float automatically activates the pump The protective cage prevents debris or other wires from interfering with the movement of the float It can be used to replace...

Page 20: ...the address listed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the co...