Chapter 2: ProtectServer External 2 Installation and Configuration
Optional Items
The following items can be used with your ProtectServer HSM. Contact your Thales sales representative to
order these items.
>
SafeNet 110 Time-Based OTP Token
(enables multifactor authentication on ProtectServer HSM tokens)
Thales recommends ordering at least two (2) OTP tokens for each slot on the HSM (one each for the
Security Officer and Token User).
PN: 955-000237-001
>
ProtectServer-compatible Verifone PIN pad
(enables manual key component entry)
PN: 934-000087-001
Installing the ProtectServer External 2 Hardware
Since the ProtectServer External 2 is delivered with the necessary software pre-installed, no software
installation is necessary on the unit itself.
After installation, confirm that the unit is operating correctly and configure the network settings. These steps
are covered in
"First Login and System Test" on page 28
and
"Network Configuration" on page 31
To install the hardware
1.
Choose a suitable location to site the equipment. You can mount the ProtectServer External 2 in a standard
19-inch rack.
NOTE
The power supply cord acts as the unit's disconnect device. The main outlet socket to
which the unit is connected must be easily accessible.
2.
Connect the ProtectServer External 2 to the network by inserting standard Ethernet cables into the LAN
connectors located on the unit's front face (labelled
eth0
and
eth1
). The client machine(s) with SafeNet
cryptographic API software installed should be hosted on the same network.
NOTE
The ProtectServer External 2 is equipped with two NICs (
eth0
and
eth1
) incorporating
an IPv4/IPv6 dual stack, allowing you to configure both an IPv4 and IPv6 address on each
interface. If you intend to use both NICs, connect Ethernet cables to both LAN connectors.
3.
Connect the power cable to the unit and a suitable power source. The ProtectServer External 2 is equipped
with an autosensing power supply that can accept 100-240V at 50-60Hz.
Thales ProtectServer HSM 5.9.1 ProtectServer HSM and ProtectToolkit Installation and Configuration Guide