Specifications
- 16 -
®
Affinity LBD-200C-N1 Transmitter
Product Manual
Parameter
Specification
Test Conditions/ Notes
equipment temperature or RF reverse
power limits are severely exceeded
Transmitter start up time
From Cold or long AC absence
From Standby
From Reset
< 10 seconds
< 7 seconds
< 7 seconds
Time measure; from AC application to
RF output enabled and at nominal
output power.
Single frequency network timing
The transmission timing of each
Transmitter site with respect to all
others in the network controlled to
within a tolerance of 300nS
Parameter
Specification
Notes / Test Conditions
Exciter
Transmission Characteristics
Emission standard: DVB-H
Modulation scheme: COFDM
Bandwidth: 5, 6, 7, or 8 MHz
Environmental and Safety
Guaranteed performance: 0
o
to 45
o
up
to 3000m
Safety: IEC215, IEC1010
Acoustic noise: IEC 179: <65dBa
General Mechanical
Rack: 19” 2U, depth 450mm
Cooling: 4 internal fans, front to rear
Input Power
Voltage: 230V/105V ±15%
Frequency: 47-63 Hz
Consumption: <200VA
Transport Stream Input
Dual A and B ASI inputs
RF Output
Standard: DVB-H
Power: 0 dBm
Output connector: 50ohm, BNC
Frequency: agile between 40-862 MHz
Intrinsic Signal Quality
Global MER: >38dB
MER per carrier: >38dB
EVM on each carrier: < 1%
BER before Viterbi: < 1x10
-6
END: <0.1 dB
In band frequency response: < ± 0.2dB
Group delay ripple: < ± 10ns
Intrinsic Out of band Emissions
Shoulders at ± 500kHz: > 46dB
Shoulders at ± 10 MHz: > 50dB
Spurious < 1GHz: >50dB
Transmission Characteristics