Venus Supply Co., Ltd. Page 8
From the circuit above, control signals are P0-
P7, PL and BUSY. Whenever that BUSY is “High”, the
module is ready to accept new parallel command. The user can send a command to P0-P7 then send
a “Low”
strobe pulse on PL. Commands are listed below:
Command Word
Function
BIN
HEX DEC
P7 P6 P5 P4 P3 P2 P1 P0
0 0 0 0 0 0 0 1 0x01
001
Play the first file
0 0 0 0 0 0 1 0 0x02
002
Play the second file
…
….
…
…
…
….
….
…
…
…..
….
1 1 0 0 0 1 1 1 0xC7
199
Play the 199
th
file
1 1 0 0 1 0 0 0 0xC8
200
Set volume level to 0 (the lowest level)
1 1 0 0 1 0 0 1 0xC9
201
Set volume level to 1
…
….
…
…
…
….
….
…
…
…..
….
1 1 1 0 0 1 1 1 0xE7
231
Set volume level to 31 (the highest level)
1 1 1 0 1 0 0 0 0xE8
232
Increase volume by 1 level
1 1 1 0 1 0 0 1 0xE9
233
Decrease volume by 1 level
1 1 1 0 1 0 1 1 0xEB
235
Pause playback
1 1 1 0 1 1 0 0 0xEC
236
Resume playback
1 1 1 0 1 1 1 1 0xEF
239
Stop playback
1 1 1 1 0 0 0 1 0xF1
241
Change directory to 01 (Root directory)
1 1 1 1 0 0 1 0 0xF2
242
Change directory to 02
…
….
…
…
…
….
….
…
…
…..
….
1 1 1 1 1 1 1 1 0xFF
255
Change directory to 15