Note that stopping the release of product as done in this example could result in a
product left partially on the powered curve with the trailing end on the stopped
discharge end of the accumulation conveyor. If this is a concern, a photo sensor
should be added to the discharge zone, with appropriate logic to insure that no
products are stopped partially released. This could require the addition of PLC
based logic.