IOM CRUZcontrol® Generation2 for NBC
P/N: 1118211
Revision Date: 05/31/2019
Page
33
of
66
5.2: O
NE
P
OWER
S
UPPLY USED TO POWER TWO SEPARATE
CRUZ
CONTROL SECTIONS
This drawing illustrates the use of one power supply to power two separate, short CRUZcontrol
sections on two different conveyors. This can be done to make better use of the full capacity of a
power supply.
It could be necessary to extend the T Cable leads to reach the power supply location. This should be
done with a wire gauge large enough to prevent noticeable voltage drop. The number of CRUZcontrol
zones that can be connected per string must also be reduced based on the voltage drop of the wire
used.
The brown lead on the T Cable connects to +24 VDC on the power supply. The blue lead on the T
Cable connects to 0 VDC on the power supply.
Figure 9: Two Separate CRUZcontrol Sections