10.2.4 E3(indoor fan speed out of control) diagnosis and solution
10.2.5 E5(Open or short circuit of outdoor temperature sensor) diagnosis and solution.
10.2.6 E6(open or short circuit of room or evaporator temperature sensor) diagnosis and solution.
10.2.7 P0(IGBT over-strong current protection) diagnosis and solution.
Is all connections on PCB
and between PCB and
compressor good?
Repair or correct the
connector or connection.
Replace the outdoor PCB
and then repower on. Is
the failure cleared?
NO
YE
Check the compressor
NO
Is the indoor temperature
and evaporator sensor
connector and connection
good?
Repair the connector and
reconnect
Replace the sensor and
check if E6 display again?
NO
YES
Replace the indoor PCB
YES
Is the outdoor temperature
sensor connector and
connection good?
Repair the connector and
reconnect
Replace the sensor and
check if E5 display again?
NO
YES
Replace outdoor e-box
YES
Is the indoor fan motor
connector and connection
good?
Repair the connector and
reconnect
Is voltage being applied to
the fan motor?
(rang 90v-160v between
mid pin and N on CN1
NO
YES
Indoor PCB is defective.
Replace the indoor PCB.
YES
Replace the indoor fan
motor
NO
Summary of Contents for MWVT09S
Page 1: ......
Page 17: ...Service manual 16 5 Refrigerant cycle diagram Cooling only mode Heat pump mode ...
Page 19: ...Service manual 18 MRVT09AS MRVT12AS Outdoor unit ...
Page 20: ...Service manual 19 MRHVT09AS MRHVT12AS Outdoor unit ...
Page 21: ...Service manual 20 MRVT18AS MRHVT18AS Outdoor unit ...
Page 22: ...Service manual 21 MWVT24S MWHVT24S Indoor unit ...
Page 23: ...Service manual 22 MRVT24AS Outdoor unit ...