- 43 -
10.1 Indoor Unit Error Display
Display
LED STATUS
E0 EEPROM
parameter
error
E1
Indoor / outdoor units communication protection
E2 Zero-crossing
signal
error
E3
Fan speed out of control
E5
Open or short circuit of outdoor ambient or condenser temperature sensor
E6
Open or short circuit of indoor room or evaporator temperature sensor
P0
Inverter module (IGBT) over-strong current protection
P1
Over voltage or too low voltage protection
P2
Temperature protection of compressor top.
P4 Inverter
compressor
drive
error
Note: E4 & P3: Reserved function
10.2 Diagnosis and Solution
10.2.1 E0(EEPROM parameter error) error diagnosis and solution
Circuit or software error on indoor PCB
Replace indoor PCB