Service manual
- 25 -
8.4 Air purging of the piping and indoor unit
Required tools:
Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak detector.
Note:
The air in the indoor unit and in the piping must be purged. If air remains in the refrigeration piping, it will affect the
compressor, reduce the cooling capacity, and could lead to a malfunction of unit.
Be sure, using a torque wrench to tighten the service port cap (after using the service port), so that it prevents the gas
leakage from the refrigeration cycle.
Procedure
:
1. Recheck
the
piping
connections.
2. Open the valve stem of the 2-way valve counterclockwise approximately 90’, wait 10 seconds, and then set it to
closed position.
Be sure to use a hexagonal wrench to operate the valve stem
3. Check for gas leakage.
Check the flare connection for gas leakage
4. Purge the air from the system.
5. Set the 2-way valve to the open position and remove the cap from the 3-way valve’s service port.
6. Using the hexagonal wrench to press the valve core pin, discharge for three seconds and then wait for one minute.
7. Use torque wrench to tighten the service port cap to a torque of 1.8 kg.m. (18n.m)
8. Set the 3-way valve to the opened position.
9. Mounted the valve stem nuts to the 2-way and 3-way valves.
10. Check for gas leakage.
11. At this time, especially check for gas leakage from the 2-way and 3-way stem nuts, and from the service port.
Caution:
If gas leakage is discovered in step (3) above, take the following measures.
If the leaks stop when the piping connections are tightened further, continue working from step (4).
If the gas leaks do not stop when the connections are retightened, repair the location of the leak, discharge all of the gas
through the service port, and then recharge with the specified amount of gas from a gas cylinder.
Summary of Contents for MWVT09S
Page 1: ......
Page 17: ...Service manual 16 5 Refrigerant cycle diagram Cooling only mode Heat pump mode ...
Page 19: ...Service manual 18 MRVT09AS MRVT12AS Outdoor unit ...
Page 20: ...Service manual 19 MRHVT09AS MRHVT12AS Outdoor unit ...
Page 21: ...Service manual 20 MRVT18AS MRHVT18AS Outdoor unit ...
Page 22: ...Service manual 21 MWVT24S MWHVT24S Indoor unit ...
Page 23: ...Service manual 22 MRVT24AS Outdoor unit ...