Self-fault diagnostic function
28
Our company will provide convenient service to our customers, and install
all kinds of judgment systems, which can display the unmoral function of the unit .
Indoor fault codes table
Timer light flashing
4LED
Faults
Digital display
E2
Ambient temperature
sensor (T1) failure
Failure descriptionction
Running light flashing
E3
Evaporator pipe temperature
sensor (T2) failure
Defrost light flashing
E5
Condenser pipe temperature
sensor (T3) failure
Warning light flashing
F5
Water fullfilled protection
Running light,
defrost light flashing
E1
Indoor unit EEPROM failure
Running light, timer light flashing
P6
Indoor fan stall protection
(
DC Motor
)
Defrost light, timer light flashing
Outdoor protection
(
220V Communication control
)
F2
outdoor unit over-current protection
(
Reserve
)
Defrost light,
warning light flashing
F7
Indoor unit and outdoor
unit communication failure
(
Communication control
)
RS485
Timer light, warning light flashing
E0
High pressure protection
(
Communication control
)
RS485
Running light, defrost light,
timer light flashing
F3
Low pressure protection
(
Communication control
)
RS485
Defrost light , timer light,
warning light flashing
F4
Outdoor unit exhaust
temperature
over
-
high protection
(
Communication control
)
RS485
Running light, timer light,
warning light flashing
F8
Three-phase electricity
phase sequence failure
(
Communication control
)
RS485
F9
Running light, defrost light,
timer light, warning light flashing
Note: the flashing frequency for all above indication lights is 1HZ.
F0
Indoor unit and wire controller
communication failure