background image

©Copyright Task Force Tips LLC   2017-2018 

LIY-210 September 17, 2018 Rev01

7

3.2  SPECIFICATIONS
3.2.1  MECHANICAL

Electric

US

METRIC

Weight

14.2 lbs

6.5 kg

Min. Flow Area 1.5” Inlet

1.77 in

2

 

11.4 cm

2

Min. Flow Area 2.0” Inlet

3.14 in

2

 

20.3 cm

2

Max Flow

See fi gure 3.2.2

Max Operating Pressure

200 psi 

14 bar

Horizontal Travel Range

270° (135° left and right)

Materials Used

ANSI A356.0-T6 Aluminum, 

Stainless

Maximum Torque Elevation

26 ft•lbs

35 n•m

Maximum Torque Horizontal

26 ft•lbs

35 n•m

Speed Elevation

33 deg/sec

Speed Horizontal

33 deg/sec

 3.2.2 SAFE OPERATING ENVELOPE

 

0

200

400

600

800

1000

1200

0

2

4

6

8

10

12

14

0

25

50

75

100

125

150

175

200

225

0

50

100

150

200

250

300

Flow (lpm)

Pr

e

ss

u

re

 (

ba

r)

P

re

ssu

re

 (

p

si

)

Flow (gpm)

EF1 Opera

Ɵ

ng Envelope

Nozzle 

Pressure

Monitor Inlet  

Pressure

K=2
NOZZLE

K=8
NOZZLE

K=15
NOZZLE

K=20
NOZZLE

MONITOR LOSS

Nozzle A fl ows 20 gpm (80 l/min) at 100 psi (7 bar), K factor = 2 

Nozzle B fl ows 80 gpm (300 l/min) at 100 psi (7 bar), K factor = 8

Nozzle C fl ows 150 gpm (570 l/min) at 100 psi (7 bar), K factor = 15

Nozzle D fl ows 200 gpm (760 l/min) at 100 psi (7 bar), K factor = 20

Figure 3.2.2

Safe Operating Envelope

Summary of Contents for EF1

Page 1: ... tft com serial number This instruction manual is intended to familiarize firefighters and maintenance personnel with the operation servicing and safety procedures associated with the EF1 RC Monitor series This manual should be kept available to all operating and maintenance personnel TASK FORCE TIPS LLC MADE IN USA TFT COM 3701 Innovation Way Valparaiso IN 46383 9327 USA 800 348 2686 219 462 6161 F...

Page 2: ...uipment you may be called upon to use 3 It is your responsibility to know that you have been properly trained in Firefighting and or Emergency Response and in the use precautions and care of any equipment you may be called upon to use 4 It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to us...

Page 3: ...th Display Operator Station Y4E RP D SECTION 4 4 Tethered Operator Station Y4E CT SECTION 4 5 Tethered Operator Station With Display Y4E CT D SECTION 4 6 Wireless Operator Station YE RF SECTION 4 7 Wireless Operator Station With Display YE RF D SECTION 3 0 General Information and Speci cations SECTION 4 0 Electrical Controls Installation and Operation SECTION 4 11 Monitor Position Display Y4E DISP...

Page 4: ...INSTALLATION 11 4 1 STRUCTURAL REQUIREMENTS 11 4 2 TRAVEL RANGES 11 4 2 1 TRAVEL STOPS 12 4 3 QUICK CONNECT INSTALLATION 12 4 4 NOZZLE INSTALLATION 13 4 5 PRESSURE GAGE 13 4 6 DRAINING RESIDUAL WATER 13 5 0 OPERATION OF RC MONITORS 14 6 0 RECOMMENDED PARK POSITION 14 6 1 OVERRIDE HEX DRIVE 14 7 0 FLOW CHARACTERISTICS 15 7 1 STACKED TIPS FLOW 15 7 2 EF1 RC MONITOR FRICTION LOSS 15 8 0 DRAWINGS AND ...

Page 5: ...ng a monitor is very powerful and capable of causing injury and property damage Make sure the monitor is securely attached to the base and pointing in a safe direction before water to the monitor is turned on Use care in directing the stream WARNING The monitor may be damaged if frozen while containing sufficient amounts of water Such damage may be difficult to detect visually and can lead to possible...

Page 6: ...f travel Unit has waterproof factory installed plug on power wire for easy removal or reinstallation Electric drives and control box are waterproof Main waterway made from hardcoat anodized ANSI 356 T6 aluminum Silver powder coat finish Various inlets are available 3 1 PART IDENTIFICATION REMOVE CAP TO ACCESS MANUAL OVERRIDE HEX NUT FOR ELEVATION MODEL SERIAL NUMBER ON LABEL OUTLET TURNING VANE INL...

Page 7: ...zontal 26 ft lbs 35 n m Speed Elevation 33 deg sec Speed Horizontal 33 deg sec 3 2 2 SAFE OPERATING ENVELOPE 0 200 400 600 800 1000 1200 0 2 4 6 8 10 12 14 0 25 50 75 100 125 150 175 200 225 0 50 100 150 200 250 300 Flow lpm Pressure bar Pressure psi Flow gpm EF1 OperaƟng Envelope Nozzle Pressure Monitor Inlet Pressure K 2 NOZZLE K 8 NOZZLE K 15 NOZZLE K 20 NOZZLE M O NITO R LO SS Nozzle A flows 20...

Page 8: ... Y1165 SER IAL www tft c om Y12 3456 219 462 6161 www tft c om MAD E IN USA MODEL Note Outlet thread options are machined into elbow 2 0 NPT FEMALE Y1401 2 0 BSP FEMALE Y1403 1 5 NPT FEMALE Y1400 2 0 ANSI 150 1 5 BSP FEMALE Y1402 1 5 ANSI 150 Y1412 1 5 NPT FEMALE ON INNER DIAMETER OF FLANGE 1 5 NPT FEMALE ON INNER DIAMETER OF FLANGE Y1417 Note All flanged inlets include female 1 5 NPTF thread The fl...

Page 9: ...be specified at time of order EF1 RC MODEL INLET COUPLING 2 5 7 5 NH 2 5 ANSI 150 Y2430A 3 0 ANSI 150 Y2431 1 5 NPT FEMALE Y2421A 2 5 BSP FEMALE Y2405A 2 0 BSP FEMALE Y2425A 2 5 NPT FEMALE Y2400A 2 0 NPT FEMALE Y2420A 3 0 NPT FEMALE Y2403A CODE RLF Y2413A Y1165 SER IAL www tft c om Y123456 219 462 616 1 www tft com MAD E IN USA MODEL Fig 3 4 2a Inlets ...

Page 10: ...E Y1402 2 7 in 69 mm 2 0 ANSI 150 Y1417 1 8 in 45 mm 1 5 ANSI 150 Y1412 1 7 in 43 mm 2 0 NPT FEMALE Y1401 2 7 in 69 mm 1 5 NPT FEMALE Y1400 2 7 in 69 mm Inlet Option Quick Connect Additional Overall Height 2 1 2 7 5 NH FEMALE no inlet fitting 0 00 in 0 mm 2 1 2 11 BSPT FEMALE 2 00 in 51 mm 2 0 11 BSPT FEMALE 1 50 in 38 mm DN80 PN16 2 00 in 51 mm 2 5 ANSI 150 FLANGE 2 00 in 51 mm 3 0 ANSI 150 FLANGE...

Page 11: ...E ON BOLTS in mm in mm in mm in mm ft lb N m 2 5 ANSI 150 6 9 175 0 98 25 5 5 140 4 5 8 16 76 80 100 110 3 ANSI 125 150 DN80 PN20 7 5 190 0 75 20 6 0 152 5 4 5 8 16 76 80 100 110 4 ANSI 150 DN100 PN20 9 0 230 0 94 23 7 5 190 8 5 8 16 76 80 100 110 DN80 PN16 FLANGE 7 9 200 0 87 22 6 3 160 8 5 8 16 76 80 100 110 DN100 PN16 FLANGE 8 7 220 0 87 22 7 1 180 8 5 8 16 76 80 100 110 WARNING Injury can resu...

Page 12: ... 1 2 NH Coupling Inlet With Lock Internal Ear On EF1 RC Engages This Slot On The Adapter To Give Rotational Alignment Straight Ahead Reference Mark Important Install So Straight Ahead Reference Mark Is Facing Desired Direction See Figure 4 2b Flanged Inlet Adapter Female Threaded Inlet Adapter Y116 5 SER IAL www tft com Y123456 219 462 6161 www tft com MADE IN USA MODEL Fig 4 3 Inlet Adapter and S...

Page 13: ...be greatly delayed by various coatings on the metal such as powder paint hard anodizing or silicone grease 4 5 PRESSURE GAGE Y1165 SERIAL www tft com Y123456 219 462 6161 www tft com MADE IN USA MODEL There is a raised boss on the front of the monitor This raised boss is not machined from the factory but may be drilled and tapped for NPT threads if a pressure gage is desired on the monitor Fig 4 5...

Page 14: ...ys be sure the monitor is properly parked before moving the truck and know the overall height to avoid damage from overhead obstructions such as doors or bridges See Remote Control RC Monitor Electrical Controls Supplemental Instructions LIY 500 for information on programming OSCILLATE and PARK position of the EF1 RC monitor 6 1 OVERRIDE HEX DRIVE In the event of electrical system failure on the m...

Page 15: ... 107 3 4 INCH 118 44 149 71 167 88 205 132 221 155 NOZZLE INLET PRESSURE NOZZLE DIAMETER 4 BAR 6 BAR 8 BAR 10 BAR 12 BAR FLOW l min REACTION KG FLOW l min REACTION KG FLOW l min REACTION KG FLOW l min REACTION KG FLOW l min REACTION KG 12 MM 190 9 230 14 270 18 300 23 330 28 16 MM 340 16 420 25 480 33 540 41 590 49 19 MM 480 23 590 35 680 46 760 58 830 69 Fig 8 1 Stacked Tips Flow Table 7 2 EF1 MO...

Page 16: ... September 17 2018 Rev01 16 8 0 DRAWING PARTS LIST 13 2 1 4 3 5 7 8 9 10 12 13 14 15 16 17 19 18 20 21 22 24 23 15 14 25 33 32 34 35 36 37 38 11 6 16 30 31 29 27 28 29 26 16 26 27 40 41 43 44 48 28 29 39 49 47 45 50 46 see 3 4 1 3 4 2 51 52 42 29 31 ...

Page 17: ...AP 2 Y1161 25 NAME LABEL 1 Y1165 26 1 4 20 X 3 8 BUTTON HEAD CAP SCREW 1 VT25 20BH375 27 3 8 LOOP CLAMP 1 Y4655 28 TRAVEL STOP RIGHT 1 Y1414 29 1 4 20 X 5 16 SOCKET SET SCREW 4 VT25 20SS312 30 RIGID BASE 1 5 ANSI 150 1 Y1412 See Section 3 4 1 for other inlet option part numbers 31 TRAVEL STOP LEFT 1 Y1413 32 8 32 X 3 8 SOCKET HEAD CAP SCREW 2 VT08 32SH375 33 STOP EAR 1 Y1415 34 10 32 X 1 4 SET SCR...

Page 18: ...discharge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any co...

Page 19: ...place damaged parts Elevation Binding Debris or damage to elevation drive parts Clean out debris or replace damaged parts Lack of lubricant Grease see section 11 1 May be electrical related See trouble shooting section of Electronics Manual LIY 500 Horizontal Rotation Binding Debris or damage to horizontal drive parts Clean out debris or replace damaged parts Lack of lubricant Grease see section 1...

Page 20: ...t be inspected to this list 1 All valves open and close smoothly and fully 2 The waterway is clear of obstructions 3 There is no damage to any thread or other type connection 4 The pressure setting of the relief valve if any is set correctly 5 All locks and hold down devices work properly 6 Internal gaskets are in accordance with NFPA 1962 2013 Section 7 2 7 There is no damage to the appliance tha...

Reviews: