ITEM # DESCRIPTION

QTY PART #

1

BRAND LABEL

1

Y5703

2

WARNING LABEL

1

ZB1069 

3

WASHER

5

VW312X162-62 

4

M4-0.7 X 25MM SOCKET HEAD CAP SCREW 

5

VTM4-0.7SH25 

5

ENCLOSURE LID

1

Y1116

6

O-RING-006

5

VO-006

7

O-RING-262

1

VO-262

8

6-32 X 3/16 SOCKET HEAD CAP SCREW 

4

VT06-32SH188

9

BOARD

1

Y5010

10

BOARD

1

Y5000

11

CIRCUIT BOARD STANDOFF 

2

Y5533

12

HEX PLUG

1

Y5248 

13

GREASE FITTING 1/4-28

2

VT25-28ZERK

14

 3/8-24 X 3/8 SOCKET SET SCREW 

4

VT37-24SS375

15

BALL 5/16" TORLON

100

VB.312TO

16

O-RING-229

2

VO-229

17

ELBOW

1

Y1311

18

RECEPTACLE - 6 POLE

1

Y5485

19

STRAIN RELIEF

1

Y5205

20

MOTOR MOUNT RETAINER

2

Y1910

21

DRIVE SHAFT SUBASSEMBLY

2

Y1915

22

SNAP RING

2

VR4220

23

O-RING-215

2

VO-215

24

CAP

2

Y1161

25

NAME LABEL

1

Y1165

26

1/4-20 X 3/8 BUTTON HEAD CAP SCREW

1

VT25-20BH375

27

3/8 LOOP CLAMP

1

Y4655

28

TRAVEL STOP RIGHT

1

Y1414

29

1/4-20 X 5/16 SOCKET SET SCREW 

4

VT25-20SS312 

30

RIGID BASE 1.5" ANSI 150

1

Y1412

 See Section 3.4.1 for other inlet option part numbers

31

TRAVEL STOP LEFT

1

Y1413

32

8-32 X 3/8 SOCKET HEAD CAP SCREW 

2

VT08-32SH375 

33

STOP EAR

1

Y1415

34

10-32 X 1/4 SET SCREW

1

VT10Y32SS250 

35

LOWER SECTION

1

Y1110

36

M4-0.7 X 8MM SOCKET HEAD CAP SCREW 

8

VTM4-0.7SH8 

37

MOTOR MOUNT

2

Y1164

38

HORIZONTAL MOTOR

1

Y6000

VERTICAL MOTOR

1

Y6001

39

BASE 2.5" QUICK CONNECT

1

Y1404

40

1/4-20 HEX NUT

1

VT25-20NT

41

1/4-28 X 1/2 SOCKET SET SCREW

1

VT25-28SS500

42

3/16" TORLON BALL

48

V2120-TORLON

43

COUPLING 2.5"NH

1

M306

44

GASKET - 2.0"

1

V3140

45

PULL PIN

1

XX340

46

SPACER

1

Y2319

47

PULL PIN HOUSING

1

X350

48

PULL KNOB

1

XX341

49

1/8 X 3/4 HDP SPIROL PIN

1

VP125X750H

50

SPRING

1

XX342

51

SMALLEY RING

1

VR4310

52

WIRE CLAMP BRACKET

1

Y2135

Summary of Contents for EF1

Page 1: ... tft com serial number This instruction manual is intended to familiarize firefighters and maintenance personnel with the operation servicing and safety procedures associated with the EF1 RC Monitor series This manual should be kept available to all operating and maintenance personnel TASK FORCE TIPS LLC MADE IN USA TFT COM 3701 Innovation Way Valparaiso IN 46383 9327 USA 800 348 2686 219 462 6161 F...

Page 2: ...uipment you may be called upon to use 3 It is your responsibility to know that you have been properly trained in Firefighting and or Emergency Response and in the use precautions and care of any equipment you may be called upon to use 4 It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to us...

Page 3: ...th Display Operator Station Y4E RP D SECTION 4 4 Tethered Operator Station Y4E CT SECTION 4 5 Tethered Operator Station With Display Y4E CT D SECTION 4 6 Wireless Operator Station YE RF SECTION 4 7 Wireless Operator Station With Display YE RF D SECTION 3 0 General Information and Speci cations SECTION 4 0 Electrical Controls Installation and Operation SECTION 4 11 Monitor Position Display Y4E DISP...

Page 4: ...INSTALLATION 11 4 1 STRUCTURAL REQUIREMENTS 11 4 2 TRAVEL RANGES 11 4 2 1 TRAVEL STOPS 12 4 3 QUICK CONNECT INSTALLATION 12 4 4 NOZZLE INSTALLATION 13 4 5 PRESSURE GAGE 13 4 6 DRAINING RESIDUAL WATER 13 5 0 OPERATION OF RC MONITORS 14 6 0 RECOMMENDED PARK POSITION 14 6 1 OVERRIDE HEX DRIVE 14 7 0 FLOW CHARACTERISTICS 15 7 1 STACKED TIPS FLOW 15 7 2 EF1 RC MONITOR FRICTION LOSS 15 8 0 DRAWINGS AND ...

Page 5: ...ng a monitor is very powerful and capable of causing injury and property damage Make sure the monitor is securely attached to the base and pointing in a safe direction before water to the monitor is turned on Use care in directing the stream WARNING The monitor may be damaged if frozen while containing sufficient amounts of water Such damage may be difficult to detect visually and can lead to possible...

Page 6: ...f travel Unit has waterproof factory installed plug on power wire for easy removal or reinstallation Electric drives and control box are waterproof Main waterway made from hardcoat anodized ANSI 356 T6 aluminum Silver powder coat finish Various inlets are available 3 1 PART IDENTIFICATION REMOVE CAP TO ACCESS MANUAL OVERRIDE HEX NUT FOR ELEVATION MODEL SERIAL NUMBER ON LABEL OUTLET TURNING VANE INL...

Page 7: ...zontal 26 ft lbs 35 n m Speed Elevation 33 deg sec Speed Horizontal 33 deg sec 3 2 2 SAFE OPERATING ENVELOPE 0 200 400 600 800 1000 1200 0 2 4 6 8 10 12 14 0 25 50 75 100 125 150 175 200 225 0 50 100 150 200 250 300 Flow lpm Pressure bar Pressure psi Flow gpm EF1 OperaƟng Envelope Nozzle Pressure Monitor Inlet Pressure K 2 NOZZLE K 8 NOZZLE K 15 NOZZLE K 20 NOZZLE M O NITO R LO SS Nozzle A flows 20...

Page 8: ... Y1165 SER IAL www tft c om Y12 3456 219 462 6161 www tft c om MAD E IN USA MODEL Note Outlet thread options are machined into elbow 2 0 NPT FEMALE Y1401 2 0 BSP FEMALE Y1403 1 5 NPT FEMALE Y1400 2 0 ANSI 150 1 5 BSP FEMALE Y1402 1 5 ANSI 150 Y1412 1 5 NPT FEMALE ON INNER DIAMETER OF FLANGE 1 5 NPT FEMALE ON INNER DIAMETER OF FLANGE Y1417 Note All flanged inlets include female 1 5 NPTF thread The fl...

Page 9: ...be specified at time of order EF1 RC MODEL INLET COUPLING 2 5 7 5 NH 2 5 ANSI 150 Y2430A 3 0 ANSI 150 Y2431 1 5 NPT FEMALE Y2421A 2 5 BSP FEMALE Y2405A 2 0 BSP FEMALE Y2425A 2 5 NPT FEMALE Y2400A 2 0 NPT FEMALE Y2420A 3 0 NPT FEMALE Y2403A CODE RLF Y2413A Y1165 SER IAL www tft c om Y123456 219 462 616 1 www tft com MAD E IN USA MODEL Fig 3 4 2a Inlets ...

Page 10: ...E Y1402 2 7 in 69 mm 2 0 ANSI 150 Y1417 1 8 in 45 mm 1 5 ANSI 150 Y1412 1 7 in 43 mm 2 0 NPT FEMALE Y1401 2 7 in 69 mm 1 5 NPT FEMALE Y1400 2 7 in 69 mm Inlet Option Quick Connect Additional Overall Height 2 1 2 7 5 NH FEMALE no inlet fitting 0 00 in 0 mm 2 1 2 11 BSPT FEMALE 2 00 in 51 mm 2 0 11 BSPT FEMALE 1 50 in 38 mm DN80 PN16 2 00 in 51 mm 2 5 ANSI 150 FLANGE 2 00 in 51 mm 3 0 ANSI 150 FLANGE...

Page 11: ...E ON BOLTS in mm in mm in mm in mm ft lb N m 2 5 ANSI 150 6 9 175 0 98 25 5 5 140 4 5 8 16 76 80 100 110 3 ANSI 125 150 DN80 PN20 7 5 190 0 75 20 6 0 152 5 4 5 8 16 76 80 100 110 4 ANSI 150 DN100 PN20 9 0 230 0 94 23 7 5 190 8 5 8 16 76 80 100 110 DN80 PN16 FLANGE 7 9 200 0 87 22 6 3 160 8 5 8 16 76 80 100 110 DN100 PN16 FLANGE 8 7 220 0 87 22 7 1 180 8 5 8 16 76 80 100 110 WARNING Injury can resu...

Page 12: ... 1 2 NH Coupling Inlet With Lock Internal Ear On EF1 RC Engages This Slot On The Adapter To Give Rotational Alignment Straight Ahead Reference Mark Important Install So Straight Ahead Reference Mark Is Facing Desired Direction See Figure 4 2b Flanged Inlet Adapter Female Threaded Inlet Adapter Y116 5 SER IAL www tft com Y123456 219 462 6161 www tft com MADE IN USA MODEL Fig 4 3 Inlet Adapter and S...

Page 13: ...be greatly delayed by various coatings on the metal such as powder paint hard anodizing or silicone grease 4 5 PRESSURE GAGE Y1165 SERIAL www tft com Y123456 219 462 6161 www tft com MADE IN USA MODEL There is a raised boss on the front of the monitor This raised boss is not machined from the factory but may be drilled and tapped for NPT threads if a pressure gage is desired on the monitor Fig 4 5...

Page 14: ...ys be sure the monitor is properly parked before moving the truck and know the overall height to avoid damage from overhead obstructions such as doors or bridges See Remote Control RC Monitor Electrical Controls Supplemental Instructions LIY 500 for information on programming OSCILLATE and PARK position of the EF1 RC monitor 6 1 OVERRIDE HEX DRIVE In the event of electrical system failure on the m...

Page 15: ... 107 3 4 INCH 118 44 149 71 167 88 205 132 221 155 NOZZLE INLET PRESSURE NOZZLE DIAMETER 4 BAR 6 BAR 8 BAR 10 BAR 12 BAR FLOW l min REACTION KG FLOW l min REACTION KG FLOW l min REACTION KG FLOW l min REACTION KG FLOW l min REACTION KG 12 MM 190 9 230 14 270 18 300 23 330 28 16 MM 340 16 420 25 480 33 540 41 590 49 19 MM 480 23 590 35 680 46 760 58 830 69 Fig 8 1 Stacked Tips Flow Table 7 2 EF1 MO...

Page 16: ... September 17 2018 Rev01 16 8 0 DRAWING PARTS LIST 13 2 1 4 3 5 7 8 9 10 12 13 14 15 16 17 19 18 20 21 22 24 23 15 14 25 33 32 34 35 36 37 38 11 6 16 30 31 29 27 28 29 26 16 26 27 40 41 43 44 48 28 29 39 49 47 45 50 46 see 3 4 1 3 4 2 51 52 42 29 31 ...

Page 17: ...AP 2 Y1161 25 NAME LABEL 1 Y1165 26 1 4 20 X 3 8 BUTTON HEAD CAP SCREW 1 VT25 20BH375 27 3 8 LOOP CLAMP 1 Y4655 28 TRAVEL STOP RIGHT 1 Y1414 29 1 4 20 X 5 16 SOCKET SET SCREW 4 VT25 20SS312 30 RIGID BASE 1 5 ANSI 150 1 Y1412 See Section 3 4 1 for other inlet option part numbers 31 TRAVEL STOP LEFT 1 Y1413 32 8 32 X 3 8 SOCKET HEAD CAP SCREW 2 VT08 32SH375 33 STOP EAR 1 Y1415 34 10 32 X 1 4 SET SCR...

Page 18: ...discharge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any co...

Page 19: ...place damaged parts Elevation Binding Debris or damage to elevation drive parts Clean out debris or replace damaged parts Lack of lubricant Grease see section 11 1 May be electrical related See trouble shooting section of Electronics Manual LIY 500 Horizontal Rotation Binding Debris or damage to horizontal drive parts Clean out debris or replace damaged parts Lack of lubricant Grease see section 1...

Page 20: ...t be inspected to this list 1 All valves open and close smoothly and fully 2 The waterway is clear of obstructions 3 There is no damage to any thread or other type connection 4 The pressure setting of the relief valve if any is set correctly 5 All locks and hold down devices work properly 6 Internal gaskets are in accordance with NFPA 1962 2013 Section 7 2 7 There is no damage to the appliance tha...