background image

 

 

 

3. Technical parameters 

 

General features 

Power supply  

  

IEEE802.3af/at (up to 60W) 

Data transfer type  

 

10/100/1000Base-T 

Degree of protection from dust and 
moisture 

 

IP67 

Operating temperature, °C  

 

- 55...+80 

Dimensions, mm 

 

220x120x90 

Weight, kg 

 

<2 

Characteristics according to GOST IEC 61643-21 - 2014 

Protected pairs 

  

(1-2), (3-6), (4-5), (7-8) 

(1,2-3,6), (4,5-7,8) 

Nominal operating voltage, DC 

Uо  6V 

48V 

Maximum continuous operating 
voltage, DC 

Uс  9V 

57V 

Nominal current (direct) 

IL 

 

600mA+600mA 

line-ground 

 

С2 Nominal discharge current (8/20) 

In 

1 kA 

(C2 

– 2 kV/1 kA) Protection voltage 

level at In  

Up  <450 V  

C3 Protection voltage level at 

1 kV/μs 

Up  < 600 V 

Actuation time 

tA  < 100 ns 

Stray capacitance 

С  < 1 pF 

line-line 

 

 

(1-2), (3-6), (4-5), (7-8) 

(1,2-3,6), (4,5-7,8) 

С2 Nominal discharge current (8/20) 

In 

200 A 

200 A 

(В2 - 1 kV/25 A) Protection voltage 
level at In  

Up  < 15 V 

 

< 75 V 

C3 Protection voltage level at 1 kV/μs 

Up  < 20 V 

 

< 85 V 

Actuation time 

tA  <1 ns 

<1 ns 

Stray capacitance 

С  < 25 pF 

< 25 pF 

 

Bandwidth 

 

250 MHz  

Input losses  

  

< 3 dB (up to 250 MHz) 

Crosstalk at the transmitting end  

  

< 35 dB (up to 250 MHz)  

 

Summary of Contents for SG-Cam

Page 1: ...1 Operating Manual SG Cam Surge protection unit for video cameras Version 1...

Page 2: ...2 Grounding of the switch is obligatory It is recommended to check the integrity of lightning protection device at the beginning and the end of the storm season and immediately after the storm...

Page 3: ...Description 5 3 Technical parameters 7 4 Operating conditions 8 5 Installation 8 5 1 Installation on the wall or pole 8 5 2 Pulling cables through the cable gland 9 5 3 Cable connection 11 6 Supply sc...

Page 4: ...TFortis SG Switches Figure 1 Typical application scheme Features High level of protection against lightning interferences All weather performance IP67 housing Operation in a wide range of temperatures...

Page 5: ...amera grounding cable There is enough space inside SG Cam to accommodate the excess cable coming from the video camera Figure 2 2 Application of a single large cable gland with a dedicated rubber slee...

Page 6: ...6 Figure 2 2 Device interior Figure 2 3 Example of connection...

Page 7: ...C U 9V 57V Nominal current direct IL 600mA 600mA line ground 2 Nominal discharge current 8 20 In 1 kA C2 2 kV 1 kA Protection voltage level at In Up 450 V C3 Protection voltage level at 1 kV s Up 600...

Page 8: ...end of the storm season and immediately after the storm 5 Installation 5 1 Installation on the wall or pole Use M5 bolts from the supply kit to screw the brackets to the device housing Figure 5 1 Fig...

Page 9: ...rilling of the housing will lead to loss of device integrity and as a result loss of product warranty 5 2 Pulling cables through the cable gland Cut the hole in the rubber sleeve Pull the cables throu...

Page 10: ...10 Assemble the cable gland according to the Figure below Tighten the cable gland...

Page 11: ...from the video camera to RJ45 CAMERA switch If the cable from the video camera ends with a plug make an Ethernet cable of a minimum length and use it to connect the video camera Connect the grounding...

Page 12: ...12 Figure 5 3 1 Connection scheme It is recommended to use a 4 pair twisted pair at least category 5 Figure 5 3 2 Separation of the Ethernet cable 6 Supply scope...

Page 13: ...g is missing or if the serial number has been changed removed or is illegible if there are internal of external mechanical damages chipping cracking deformation damaged power supply wires cracking or...

Reviews: