background image

 

 

 

Table 2.4-2. 

T

y

pe

 of

 i

mp

ac

Degree 

of 

tes

t s

ev

erit

y

 

T

es

t v

ol

ta

ge

% Un, +

 5 

%

 

V

ol

tag

e t

ran

s

ien

ts

  

 

am

p

lit

ud

e

, % Un

 

V

ol

tag

e t

ran

s

ien

ts

  

du

rati

on

int

erv

al

s

 (

ms

Voltage dips 

70 

30 

10 (200) 

Voltage 

interruptions 

0 to 20 

100 

1 (20) 

Voltage surges 

120 

20 

25 (500) 

Note: Un is the nominal power supply voltage. 

 
("Performance criteria B" means temporary disruption of performance or 
functioning with further recovery without operator's intervention) 
Continued operation with changes in the supply voltage from ~187 to 
~246V. 
 

2.5. Restarting cameras in case of hanging 

 
PSW-1-45-WiFi switch continuously monitors traffic intensity of the camera. 
If network activity is lost, the switch will reboot the camera by disconnecting 
PoE power supply. This function is activated by a jumper for each particular 
port. 
 
 
 

Summary of Contents for PSW-1-45-WiFi

Page 1: ...h conducting elements of the power supply unit under voltage Before connecting a laptop to port 5 of the switch put Passive PoE jumpers into the OFF position For effective lightning protection the fol...

Page 2: ...2 5 Restarting cameras in case of hanging 8 3 Technical parameters 9 4 Operating conditions 9 5 Installation 10 5 1 Unit mounting 10 5 1 1 Wall mounting 10 5 1 2 Mounting on the pole 11 5 1 3 Installa...

Page 3: ...et switch used for the construction of IP video surveillance networks 220 VAC 10 100Base Tx 10 100Base TX PoE Figure 1 1 PSW 1 45 WiFi switch connection over twisted pair 220 VAC 10 100Base Tx PoE 24V...

Page 4: ...r supply is defined by jumpers Passive PoE support 24V Port 5 supports Passive PoE 24V which allows to connect wireless access points such as Ubiquiti or MikroTik Connection to 220V A built in power s...

Page 5: ...5 2 Description 2 1 Appearance Figure 2 1 1 PSW 1 45 WiFi switch exterior view Figure 2 1 2 PSW 1 45 WiFi switch interior view circuit breakers are not included...

Page 6: ...6 2 2 Components layout Figure 2 2 Layout of components inside PSW 1 45 WiFi switch During normal processor operation CPU indicator should blink in 2 second intervals 1 second ON 1 second OFF...

Page 7: ...wer circuits from common mode and differential electromagnetic interferences The switch is resistant to powerful microsecond pulse interferences according to GOST R 51317 4 5 standard with the degree...

Page 8: ...ge Performance criteria B means temporary disruption of performance or functioning with further recovery without operator s intervention Continued operation with changes in the supply voltage from 187...

Page 9: ...EE 802 3x flow control support PoE and data transfer distance up to 100 m Power supply PSU voltage 220V 187 to 246V PoE power budget 50W maximum maximum power consumption 60W Design dimensions 240x160...

Page 10: ...0 C 67 to 122 F 5 Installation 5 1 Unit mounting 5 1 1 Wall mounting The housing has four attachment points at the edges Marking of the attachment points is shown in Figure 5 1 1 226 146 4 PSW 1 45 Wi...

Page 11: ...tis CrossBox cabinet TFortis PSW 1 45 WiFi switches have a hermetically sealed housing of technopolymer providing IP66 protection rating This ensures safe outdoor installation without the need for an...

Page 12: ...anty WARNING The switch contains static power supply units and therefore is a reactive load Inrush currents that occur during charging of the input capacitors will exceed nominal current values To pre...

Page 13: ...illegible if there are internal or external mechanical damages chipping cracking deformation damaged power supply wires cracking or splitting of the terminals signs of treatment with aggressive chemic...

Reviews: