background image

20

21

Outdoor values reception

 

y

After the batteries are inserted, the outdoor values of the outdoor sensors will be transmitted  
to the base station. 

 

y

The base station will scan the outdoor values of the transmitters. The reception symbols of the tempera-
ture-humidity sensor (Fig.1-C7), the wind sensor (Fig.1-E1) and the rain sensor (Fig.1-D1) are flashing. 

 

y

If reception is successful, beeps sound and the outdoor values are permanently displayed. 

 

y

Outdoor temperature and humidity appear on the display (Fig.1-C3+C4).  

 

y

The rainfall amount (initially 0.0 mm) (Fig.1-D5) and the wind speed (initially 0.0 km/h) (Fig.1-E5) are 
displayed. To simulate values, move the rocker (Fig.3-E) or the wind wheel (Fig.4-A) (transmission time rain 
sensor: 90 seconds, wind sensor: 31 seconds).

 

y

If the reception of the outdoor values fails within three minutes, “- -“ appears on the display. Check the batter-
ies and try it again. Check if there is any source of interference. 

 

y

You can also start the outdoor transmitters search manually later (e.g. if the transmitter is lost or if  
the batteries are changed):

 

y

Press and hold the CHANNEL button (Fig.1-N) for three seconds to search for the temperature-humidity 
sensor. Press the TX button (Fig.2-F)button in the transmitter’s battery compartment (Fig.2-H). 

 

y

Press and hold the RAIN button (Fig.1-G) for three seconds to search for the rain sensor. 

 

y

Press and hold the WIND button (Fig.1-H) for three seconds to search for the wind sensor.

 

y

A beep will sound. The registered transmitter will be cancelled. The reception symbol of the transmitter 
flashes and the base station will scan the outdoor values.

Reception of the DCF frequency signal

 

y

After the reception of the outdoor values, the clock will now scan the DCF frequency signal and the DCF 
symbol flashes on the display (Fig.1-B1). 

 

y

When the time code is successfully received after 3-10 minutes, the radio-controlled time and the DCF  
symbol will be shown steadily on the display.

 

y

The DCF reception always takes place at 1:00 and 2:00 o’clock in the morning. If the reception was not 
successfully received, further attempts will be taken at 3:00, 4:00 and 5:00 o’clock. 

 

y

You can also activate the DCF reception manually. Press the SET button (Fig.1-M).  
The DCF reception symbol flashes. 

 

y

There are 3 different reception symbols:

 

y

 flashing symbol: 

reception is active

 

y

 solid: 

 

reception is successful

 

y

no symbol: 

 

no DCF reception 

 

y

If the clock cannot detect the DCF-signal (e.g. due to interference, transmitting distance, etc.), the time can 
be set manually.

 

y

The clock will then work as a normal quartz clock (see: “Manual settings”).

Note on radio-controlled time

 

y

The time is transmitted from an atomic clock near Frankfurt am Main by a DCF-77 (77.5 kHz) frequency 
signal with a range of about 1,500 km. Your radio-controlled clock receives the signal, converts it and always 
shows the exact time. The adjustment of Daylight Saving Time and Standard Time is also automatic. 

 

y

During night-time, the atmospheric interference is usually less severe. A single daily reception is adequate to 
keep the accuracy deviation under 1 second. In extreme cases, please place the unit close to a window to 
improve reception. 

Operation

 

y

During the operation, all successful settings will be confirmed by a brief beep tone. Provided that in the 
setting mode the button tone is activated (BEEP ON).

 

y

The device will automatically quit the setting mode if no button is pressed for 10 seconds.

 

y

Press the ALERTS button (Fig.1-O) to quit the setting mode.

 

y

Press and hold the + or - button (Fig.1-K+L) in setting mode for fast mode.

Manual settings

 

y

Press and hold the SET button (Fig.1-M) for three seconds to enter the setting mode.

 

y

Beep ON (default) flashes on the display. Press the + or - button (Fig.1-K+L) to deactivate (OFF) or activate 
again the button tone.

 

y

Confirm the setting with the SET button.

 

y

The next adjustable value flashes on the display.

 

y

Use the + or - button to make the desired setting. 

 

y

Confirm with the SET button and go to the next setting.

 

y

The sequence is shown as follows: 

 

y

Button tone ON/OFF (default: BEEP ON)

 

y

DCF reception ON/OFF (default: DCF ON)

 

y

Time zone -12/+12 (default: 0H)

 

y

Hour, minute (Fig.1-B2)

 

y

Year, month, day (Fig.1-B3)

 

y

Atmospheric pressure setting (default: 1013 hPa) (Fig.1-F2)

 

y

Unit of the wind speed (km/h (default), m/s or bft) (Fig.1-E5)

 

y

Average wind speed (AVG 10, default) or maximum wind speed (TOP 1HR) (Fig.1-E6)

 

y

Prevailing wind direction, optionally as cardinal points (default) or degrees (Fig.1-E4)

 

y

Day-of-week language (default: GER) (Fig.1-B3)

DCF reception  

 

y

By default, the DCF reception is activated (DCF ON) and after successful reception of the DCF signal no 
manual time setting is necessary.

 

y

Once the DCF time reception is deactivated (DCF OFF) the clock must be manually set. 

 

y

If the DCF reception is activated, the manually set time will be overwritten by the DCF time when the signal is 
received successfully.

Time zone setting 

 

y

In the setting mode you can make the time zone correction

 

y

The time zone correction is needed for countries where the DCF signal can be received but the time zone is 
different from the DCF time (e.g. +1=one hour plus).

Atmospheric pressure setting

 

y

The relative atmospheric pressure (Fig.1-F2) is referred to the sea level’s pressure and has to be adjusted 
first to your local altitude. Ask for the current atmospheric pressure of your home area (Local weather service, 
Internet, optician, calibrated instruments in public buildings and airport).

Day-of-week language setting

 

y

In the setting mode you can choose the day-of-the-week language.

 

y

Day-of-the-week language: German (GER), English (ENG), French (FRE), Italian (ITA), Dutch (DUT), Spanish 
(SPA), Swedish (SWE) and Czech (CZE).

Temperature and humidity 
Trend arrows

 

y

The trend arrows (Fig.1-A4+C8) indicate whether the values for temperature and humidity of the last 15 
minutes are increasing, steady or decreasing.

 

   Temperature/humidity are increasing

 

   Temperature/humidity are steady (change < 0.5°C/2%) 

 

   Temperature/humidity are decreasing

Maximum and minimum values

 

y

Press several times the TEMP button (Fig.1-J) button in normal mode. 

 

y

You can now see the highest (HI) and lowest values (LO) (Fig.1-A3+C5) ) since the last reset with time and 
date of recording.

 

y

The sequence is shown as follows: Indoor temperature (HI/LO), indoor humidity (HI/LO), outdoor temperature 
(HI/LO), outdoor humidity (HI/LO).

 

y

If you have connected more than one temperature-humidity sensor, the highest and lowest values for addition-
al channels appear.

 

y

Press the TEMP button once more, to go back to the current values display. 

 

y

The device will automatically quit the HI/LO mode if no button is pressed.

 

y

Press and hold the - button (Fig.1-L) for 3 seconds while the maximum or minimum values are displayed to 
clear the recorded readings (display - -). 

Summary of Contents for 35.1161.01

Page 1: ...Kat Nr 35 1161 01 Weather PRO Funk Wetterstation Bedienungsanleitung Instruction manual Mode d emploi Istruzioni per l uso Gebruiksaanwijzing Instrucciones de uso...

Page 2: ...a u b de gebruiksaanwijzing aandachtig door De gebruiksaanwijzing is bij het apparaat gevoegd of kan worden gedownload van www tfa dostmann de en service downloads instruction manuals Gebruik het pro...

Page 3: ...4 5 Fig 1 A1 B1 B2 B3 B4 C1 C2 C3 C4 C5 C6 C7 C8 D1 E1 E2 E3 E4 E5 E6 E7 E9 E8 E10 F1 G H J K L M N O P R S F2 F3 D2 D3 D4 D5 D6 D7 A2 A3 A4 Fig 2 Fig 3 A A B D E F F F F C F G B C H D E J...

Page 4: ...eratur y Regenmenge heute mit grafischer Darstellung y Anzeige der Regenmenge der letzten Stunde der letzten 24 Stunden der letzten 7 Tage des aktuellen Monats des laufenden Jahres und gesamt y Monatl...

Page 5: ...atteriefach Fig 1 S St nder ausklappbar Thermo Hygro Sender Fig 2 Regensender Fig 3 Display Tasten Geh use Geh use Fig 2 A Kanal 1 2 3 Fig 2 B bertragungssignal Fig 2 C Temperatur Fig 2 D Luftfeuchtig...

Page 6: ...ie die ALERTS Taste Fig 1 O um den Einstellmodus zu verlassen y Halten Sie die oder Taste Fig 1 K L im Einstellmodus gedr ckt gelangen Sie in den Schnelllauf Manuelle Einstellungen y Halten Sie die SE...

Page 7: ...ckt wird Windrichtung y Die Windrichtung wird auf der LCD Windrose Fig 1 E9 durch das gro e Dreieck angezeigt 16 Windrichtungen y Dar ber hinaus wird die vorherrschende Windrichtung PREVAILING DIRECT...

Page 8: ...en w hlen Sie mit dem CH 1 2 3 Schiebeschalter Fig 2 G im Batteriefach des Au ensenders f r jeden Au ensender einen anderen Kanal aus Legen Sie dann je zwei neue Batterien 1 5 V AA polrichtig ein Nehm...

Page 9: ...Rain sensor Cat No 30 3233 01 y Solar powered wind sensor Cat No 30 3251 10 y Wind sensor support y Assembly material for the wind sensor y Instruction manual Range of application and all the bene ts...

Page 10: ...ery compartment Fig 1 S Stand fold out Temperature humidity sensor Fig 2 Rain sensor Fig 3 Display Button housing Housing Fig 2 A Channel 1 2 3 Fig 2 B Transmission signal Fig 2 C Temperature Fig 2 D...

Page 11: ...ded that in the setting mode the button tone is activated BEEP ON y The device will automatically quit the setting mode if no button is pressed for 10 seconds y Press the ALERTS button Fig 1 O to quit...

Page 12: ...on the LCD wind rose Fig 1 E9 indicates the wind direction 16 wind directions y In addition the PREVAILING DIRECTION Fig 1 E4 of the last hour is displayed In the setting mode you can choose between...

Page 13: ...he CH 1 2 3 switch Fig 2 G inside the transmitter s battery compartment Insert two new AA 1 5 V batteries polarity as illustrated Start the base station operation or the manual search for the outdoor...

Page 14: ...ance with the EU Waste Electrical and Electronic Equipment Directive WEEE Please do not dispose of this product in ordinary household waste As a consumer you are required to take end of life devices t...

Page 15: ...Kat Nr 35 1161 01...

Reviews: