Textron Keithley System SourceMeter 2601B-PULSE Quick Start Manual Download Page 3

Safety

Do not touch any object that could provide a current path to the common side of the circuit under 

test or power line (earth) ground. Always make measurements with dry hands while standing on 

a dry, insulated surface capable of withstanding the voltage being measured.
For safety, instruments and accessories must be used in accordance with the operating 

instructions. If the instruments or accessories are used in a manner not speci

 ed in the 

operating instructions, the protection provided by the equipment may be impaired. 
Do not exceed the maximum signal levels of the instruments and accessories. Maximum signal 

levels are de

 ned in the speci

 cations and operating information and shown on the instrument 

panels, test 

 xture panels, and switching cards. 

When fuses are used in a product, replace with the same type and rating for continued 

protection against 

 re hazard. 

Chassis connections must only be used as shield connections for measuring circuits, NOT as 

protective earth (safety ground) connections. 
If you are using a test 

 xture, keep the lid closed while power is applied to the device under test. 

Safe operation requires the use of a lid interlock.
If a        screw is present, connect it to protective earth (safety ground) using the wire 

recommended in the user documentation.

The         symbol on an instrument means warning, risk of electric shock. Use standard safety 

precautions to avoid personal contact with these voltages.

The       symbol indicates a connection terminal to the equipment frame.

The         symbol on an instrument means caution, risk of hazard. The user must refer to the 

operating instructions located in the user documentation in all cases where the symbol is 

marked on the instrument.

The         symbol on an instrument shows that the surface may be hot. Avoid personal contact to 

prevent burns.

If this         symbol is on a product, it indicates that mercury is present in the display lamp. Please 

note that the lamp must be properly disposed of according to federal, state, and local laws.

The 

WARNING

 heading in the user documentation explains hazards that might result 

in personal injury or death. Always read the associated information very carefully before 

performing the indicated procedure.
The 

CAUTION

 heading in the user documentation explains hazards that could damage the 

instrument. Such damage may invalidate the warranty.
The 

CAUTION

 heading with the        symbol in the user documentation explains hazards that 

could result in moderate or minor injury or damage the instrument. Always read the associated 

information very carefully before performing the indicated procedure. Damage to the instrument 

may invalidate the warranty.
Instrumentation and accessories shall not be connected to humans. 
Before performing any maintenance, disconnect the line cord and all test cables. 
To maintain protection from electric shock and 

 re, replacement components in mains circuits 

— including the power transformer, test leads, and input jacks — must be purchased from 

Keithley. Standard fuses with applicable national safety approvals may be used if the rating and 

type are the same. The detachable mains power cord provided with the instrument may only be 

replaced with a similarly rated power cord. Other components that are not safety-related may 

be purchased from other suppliers as long as they are equivalent to the original component 

(note that selected parts should be purchased only through Keithley to maintain accuracy 

and functionality of the product). If you are unsure about the applicability of a replacement 

component, call a Keithley o

  ce for information. 

Unless otherwise noted in product-speci

 c literature, Keithley instruments are designed to 

operate indoors only, in the following environment: Altitude at or below 2,000 m (6,562 ft); 

temperature 0 °C to 50 °C (32 °F to 122 °F); and pollution degree 1 or 2. 
To clean an instrument, use a cloth dampened with deionized water or mild, water-based 

cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the instrument 

or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with 

no case or chassis (e.g., a data acquisition board for installation into a computer) should never 

require cleaning if handled according to instructions. If the board becomes contaminated and 

operation is a

 ected, the board should be returned to the factory for proper cleaning/servicing. 

Safety precaution revision as of June 2017.

Summary of Contents for Keithley System SourceMeter 2601B-PULSE

Page 1: ...Model 2601B PULSE System SourceMeter Instrument Quick Start Guide ...

Page 2: ...r high transient overvoltages often associated with local AC mains connections Certain Keithley measuring instruments may be connected to mains These instruments will be marked as category II or higher Unless explicitly allowed in the specifications operating manual and instrument labels do not connect any instrument to mains Exercise extreme caution when a shock hazard is present Lethalvoltage may...

Page 3: ...ad the associated information very carefully before performing the indicated procedure The CAUTION heading in the user documentation explains hazards that coulddamage the instrument Such damage may invalidate the warranty The CAUTION heading with the symbol in the user documentation explains hazards that could result in moderate or minor injury or damage the instrument Always read the associated i...

Page 4: ...maximum at 6 V dc 1 A maximum at 40 V dc Pulser feature output region 4 Region maximums 10 A at 20 V Maximum pulse width 1 8 ms Maximum duty cycle 1 Measurement input electrical ratings Measurement category O Voltage 40 V dc maximum HI to LO Current 3 A at 6 V dc 1 A maximum at 40 V dc Impedance Variable CAUTION Carefully consider and configure the appropriate output off state source levels and co...

Page 5: ...hooting and programming commands of the instrument Information on accessories Software for the 2601B PULSE is also available for download from the Keithley web page at tek com keithley You can search for the specific software you need Available software includes Keithley KickStart Instrument Control Software Lets you start making measurements in minutes without complex instrument programming Free ...

Page 6: ... You receive the 2601B PULSE with these accessories and documents 1 Interlock DB 25 male connector kit hardware 2 Power line cord 3 Safety interlock mating connector 4 Two RJ 45 LAN crossover cables 5 2601B P INT Rear Panel Interlock and Cable Connector Box not shown 6 Safety supplement not shown 7 Safety precautions not shown 8 Software and documentation downloads document not shown 9 Model 2601B...

Page 7: ... allowed voltage in the system is 300 V dc Cover the device under test DUT to protect the operator from flying debris in the event of a system or DUT failure Make sure any test fixture connected to the system protects the operator from contact with hazardous voltages hot surfaces and sharp objects Use shields barriers insulation and safety interlocks to accomplish this Double insulate all electric...

Page 8: ...ottom of the instrument Position the instrument so that it is easy to reach any disconnecting devices such as the power cord and the power switch Install the 2601B P INT The 2601B PULSE is shipped with the 2601B P INT Rear Panel Interlock and Cable Connector Box The 2601B P INT provides connections for an optional hardware safety interlock and simplifies test connections to the 2601B PULSE To inst...

Page 9: ...s firmly onto the terminal strips on the rear panel of the 2601B PULSE 6 Use the two 6 32 in screws provided with the 2601B P INT to secure it to the rear panel of the 2601B PULSE Wiring the interlock You can use the 2601B P INT and the 2601B PULSE digital I O port or external wiring to make interlock connections to an external device When properly connected the output of the instrument will turn ...

Page 10: ...event of a failure not using a properly grounded protective earth and grounded outlet may result in personal injury or death due to electric shock Do not replace detachable mains supply cords with inadequately rated cords Failure to use properly rated cords may result in personal injury or death due to electric shock CAUTION Operating the instrument on an incorrect line voltage may cause damage to...

Page 11: ...ent is turned on you should see A series of dots All segments of the display light A brief display showing the instrument model 2601B PULSE Line frequency detection and other startup checks The entire power up process takes approximately 30 seconds to complete When initialization is complete you see the default display screen shown below SrcA 000 000mV LimA 1 00000 A AUTO ...

Page 12: ...ol CURSOR keys Step 1 Set source function range and level 1 Press the SRC key You will see a blinking character in the SrcA value field Confirm that mV is displayed if not press the SRC key again 2 While that character is still blinking press the up or down RANGE keys until 40 V is displayed AUTO The main display screen is refreshed SrcA 00 0000 V LimA 1 00000 A AUTO 3 Press the CURSOR keys to mov...

Page 13: ... 10 0000 mA SrcA 20 0000 V LimA 10 0000mA AUTO Source limit set to 10 0000mA Step 3 Set measurement function and range 1 Press the MEAS key until the V voltage measurement function is selected In the following figure the measurement function has been set to V SrcA 20 0000 V LimA 10 0000mA AUTO Measurement function set to voltage V 2 Press the AUTO key as many times as needed to select the AUTO ran...

Page 14: ...the 20 V source value Step 6 Turn the output off When you finish making measurements turn the output off by pressing the OUTPUT ON OFF control The output indicator LED turns off NOTE These steps confirm basic functionality of your instrument Turn the instrument power OFF now To use the pulser feature you must have remote communications set up Refer to the Model 2601B PULSE Reference Manual documen...

Page 15: ...n the instrument on If an error message is displayed press the EXIT LOCAL key The 2601B PULSE will return to the default display screen For detailed information about error messages see Errors and status messages in the Model 2601B PULSE Reference Manual Next steps For more information refer to the Keithley Instruments website tek com keithley for support and additional information about the instr...

Page 16: ...S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specfication and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 2601B PULSE 903 01 Rev A April 2020 P2601B...