Port B Configuration
results to your PC to remove test results or simply delete. When finished select
“
Turn
Off USB storage
” (Android turns green) and unplug the USB cable.
Port B Configuration
Port B is typically used for loopback tests such as RFC-2544. To configure Port B
simply press on the Port-A button and select Port-B. You can select speed, cop-
per/fiber just as you do with Port-A. There are five additional buttons and no RFC-
2544 or Quick test selection in the Port-B screen along with Port-B Statistics displayed
in real time and updated every ½ seconds. Use your finger to swipe up/down to get
more Port-B statistics.
►
Clear Statistics
– Press this button to Clear all the Port-B statistics and reset the
elapsed time (ET) to zero.
►
Loopback Mode
– Selects whether Port-B is in Loopback or Through Mode.
Loopback mode will loop RX to TX of Port-B when the Loopback button is Green.
Through Mode
Through Mode you can put Port-B in series with a TX or RX of an Ethernet circuit and
monitor statistics.